Dependency:
The fault buffer is deleted (cleared) by setting p0952 to 0.
Refer to: r0945, r0947, r0948, r0949, r2109, r2130, r2133, r2136
r0963
PROFIBUS baud rate / PB baud rate
CU240D-2_DP
Access level: 3
CU240D-2_DP_F
Can be changed: -
CU250D-2_DP_F
Unit group: -
Min
0
Description:
Displays the corresponding value for the PROFIBUS baud rate.
Value:
0:
1:
2:
3:
4:
6:
7:
8:
9:
10:
11:
255:
r0964[0...6]
Device identification / Device ident
Access level: 2
Can be changed: -
Unit group: -
Min
-
Description:
Displays the device identification.
Index:
[0] = Company (Siemens = 42)
[1] = Device type
[2] = Firmware version
[3] = Firmware date (year)
[4] = Firmware date (day/month)
[5] = Number of drive objects
[6] = Firmware patch/hot fix
Note:
Example:
r0964[0] = 42 --> SIEMENS
r0964[1] = device type, see below
r0964[2] = 403 --> first part of the firmware version V04.03 (for second part, refer to index 6)
r0964[3] = 2010 --> year 2010
r0964[4] = 1705 --> 17th of May
r0964[5] = 2 --> 2 drive objects
r0964[6] = 200 --> second part, firmware version (complete version: V04.03.02.00)
Device type:
r0964[1] = 6410 --> SINAMICS G120 CU240D-2_DP
r0964[1] = 6420 --> SINAMICS G120 CU240D-2_DP_F
r0964[1] = 6411 --> SINAMICS G120 CU240D-2_PN
r0964[1] = 6421 --> SINAMICS G120 CU240D-2_PN_F
r0964[1] = 6460 --> SINAMICS G120 CU250D-2_DP_F
r0964[1] = 6461 --> SINAMICS G120 CU250D-2_PN_F
SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313
9.6 kbit/s
19.2 kbit/s
93.75 kbit/s
187.5 kbit/s
500 kbit/s
1.5 Mbit/s
3 Mbit/s
6 Mbit/s
12 Mbit/s
31.25 kbit/s
45.45 kbit/s
Unknown
Calculated: -
Scaling: -
Unit selection: -
Max
255
Calculated: -
Scaling: -
Unit selection: -
Max
-
2 Parameters
2.2 List of parameters
Data type: Unsigned16
Dyn. index: -
Func. diagram: -
Factory setting
-
Data type: Unsigned16
Dyn. index: -
Func. diagram: -
Factory setting
-
147

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g120d cu250d-2 pn-fSinamics g120d cu240d-2 pnSinamics g120d cu240d-2 pn-fSinamics g120d cu250d-2 dp-f

Table of Contents