2 Parameters
2.2 List of parameters
r2266
CO: Technology controller actual value after filter / Tec_ctr act aftFlt
CU240D-2_DP
Access level: 3
CU240D-2_PN
Can be changed: -
CU240D-2_DP_F
Unit group: 9_1
CU240D-2_PN_F
Min
- [%]
Description:
Display and connector output for the smoothed actual value after the filter (PT1) of the technology controller.
p2267
Technology controller upper limit actual value / Tec_ctrl u_lim act
CU240D-2_DP
Access level: 3
CU240D-2_PN
Can be changed: U, T
CU240D-2_DP_F
Unit group: 9_1
CU240D-2_PN_F
Min
-200.00 [%]
Description:
Sets the upper limit for the actual value signal of the technology controller.
Dependency:
Refer to: p2264, p2265, p2271
Refer to: F07426
Notice:
If the actual value exceeds this upper limit, this results in fault F07426.
p2268
Technology controller lower limit actual value / Tec_ctrl l_lim act
CU240D-2_DP
Access level: 3
CU240D-2_PN
Can be changed: U, T
CU240D-2_DP_F
Unit group: 9_1
CU240D-2_PN_F
Min
-200.00 [%]
Description:
Sets the lower limit for the actual value signal of the technology controller.
Dependency:
Refer to: p2264, p2265, p2271
Refer to: F07426
Notice:
If the actual value falls below this lower limit, this results in fault F07426.
p2269
Technology controller gain actual value / Tech_ctrl gain act
CU240D-2_DP
Access level: 3
CU240D-2_PN
Can be changed: U, T
CU240D-2_DP_F
Unit group: -
CU240D-2_PN_F
Min
0.00 [%]
Description:
Sets the scaling factor for the actual value of the technology controller.
Dependency:
Refer to: p2264, p2265, p2267, p2268, p2271
Note:
For 100%, the actual value is not changed.
p2270
Technology controller actual value function / Tec_ctr ActVal fct
CU240D-2_DP
Access level: 3
CU240D-2_PN
Can be changed: U, T
CU240D-2_DP_F
Unit group: -
CU240D-2_PN_F
Min
0
Description:
Setting to use an arithmetic function for the actual value signal of the technology controller.
Value:
0:
1:
2:
3:
Dependency:
Refer to: p2264, p2265, p2267, p2268, p2269, p2271
324
Output (y) = input (x)
Root function (root from x)
Square function (x * x)
Cube function (x * x * x)
Calculated: -
Scaling: PERCENT
Unit selection: p0595
Max
- [%]
Calculated: -
Scaling: PERCENT
Unit selection: p0595
Max
200.00 [%]
Calculated: -
Scaling: PERCENT
Unit selection: p0595
Max
200.00 [%]
Calculated: -
Scaling: -
Unit selection: -
Max
500.00 [%]
Calculated: -
Scaling: -
Unit selection: -
Max
3
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 7958
Factory setting
- [%]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 7958
Factory setting
100.00 [%]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 7958
Factory setting
-100.00 [%]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 7958
Factory setting
100.00 [%]
Data type: Integer16
Dyn. index: -
Func. diagram: 7958
Factory setting
0
SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313