2 Parameters
2.2 List of parameters
p20104
SUB 0 run-time group / SUB 0 RTG
CU240D-2_DP
Access level: 3
CU240D-2_PN
Can be changed: T
CU240D-2_DP_F
Unit group: -
CU240D-2_PN_F
Min
5
Description:
Setting parameter for the run-time group in which instance SUB 0 of the subtractor is to be called.
Value:
5:
6:
9999: Do not calculate
p20105
SUB 0 run sequence / SUB 0 RunSeq
CU240D-2_DP
Access level: 3
CU240D-2_PN
Can be changed: T
CU240D-2_DP_F
Unit group: -
CU240D-2_PN_F
Min
0
Description:
Setting parameter for the run sequence of instance SUB 0 within the run-time group set in p20104.
Note:
The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
p20106[0...1]
CI: SUB 1 inputs / SUB 1 inputs
CU240D-2_DP
Access level: 3
CU240D-2_PN
Can be changed: T
CU240D-2_DP_F
Unit group: -
CU240D-2_PN_F
Min
-
Description:
Sets the signal source of minuend X1 and subtrahend X2 of instance SUB 1 of the subtractor.
Index:
[0] = Minuend X1
[1] = Subtrahend X2
r20107
CO: SUB 1 difference Y / SUB 1 difference Y
CU240D-2_DP
Access level: 3
CU240D-2_PN
Can be changed: -
CU240D-2_DP_F
Unit group: -
CU240D-2_PN_F
Min
-
Description:
Display parameter for the difference Y = X1 - X2 of instance SUB 1 of the subtractor.
p20108
SUB 1 run-time group / SUB 1 RTG
CU240D-2_DP
Access level: 3
CU240D-2_PN
Can be changed: T
CU240D-2_DP_F
Unit group: -
CU240D-2_PN_F
Min
5
Description:
Setting parameter for the run-time group in which instance SUB 1 of the subtractor is to be called.
Value:
5:
6:
9999: Do not calculate
510
Run-time group 5
Run-time group 6
Run-time group 5
Run-time group 6
Calculated: -
Scaling: -
Unit selection: -
Max
9999
Calculated: -
Scaling: -
Unit selection: -
Max
32000
Calculated: -
Scaling: PERCENT
Unit selection: -
Max
-
Calculated: -
Scaling: PERCENT
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
9999
Data type: Integer16
Dyn. index: -
Func. diagram: 7220
Factory setting
9999
Data type: Unsigned16
Dyn. index: -
Func. diagram: 7220
Factory setting
240
Data type: U32 / FloatingPoint32
Dyn. index: -
Func. diagram: 7220
Factory setting
0
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 7220
Factory setting
-
Data type: Integer16
Dyn. index: -
Func. diagram: 7220
Factory setting
9999