2 Parameters
2.2 List of parameters
p2071
PROFIdrive SIC/SCC start send / SIC/SCC start send
CU250D-2_PN_F
Access level: 3
CU250D-2_DP_F
Can be changed: T
Unit group: -
Min
0
Description:
Sets the start for the SIC/SCC telegram (p60122) in the send words (p2051, p2061).
Dependency:
Refer to: p0922, p2079, p60122
Note:
For setting p0922/p2079, the value is preset to the end of the PZD telegram.
For p0922 equal to 999 and p2079 not equal to 999, the preset value can be increased.
The value must be set again after changing p0922/p2079.
p2072
Response receive value after PZD failure / Resp aft PZD fail
Access level: 3
Can be changed: T
Unit group: -
Min
-
Description:
Sets the response for the receive value (r2090) after PZD failure.
Bit field:
Bit
00
r2074[0...11]
PROFIdrive diagnostics bus address PZD receive / Diag addr recv
Access level: 3
Can be changed: -
Unit group: -
Min
-
Description:
Displays the PROFIBUS address of the sender from which the process data (PZD) is received.
Index:
[0] = PZD 1
[1] = PZD 2
[2] = PZD 3
[3] = PZD 4
[4] = PZD 5
[5] = PZD 6
[6] = PZD 7
[7] = PZD 8
[8] = PZD 9
[9] = PZD 10
[10] = PZD 11
[11] = PZD 12
Note:
Value range:
0 - 125: Bus address of the sender
65535: Not assigned
r2075[0...11]
PROFIdrive diagnostics telegram offset PZD receive / Diag offs recv
Access level: 3
Can be changed: -
Unit group: -
Min
-
Description:
Displays the PZD byte offset in the PROFIdrive receive telegram (controller output).
278
Signal name
Unconditionally open holding brake (p0855) Freeze value
Calculated: -
Scaling: -
Unit selection: -
Max
30
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
Data type: Unsigned8
Dyn. index: -
Func. diagram: 2423
Factory setting
0
Data type: Unsigned32
Dyn. index: -
Func. diagram: -
Factory setting
0000 bin
0 signal
Zero the value
Data type: Unsigned16
Dyn. index: -
Func. diagram: -
Factory setting
-
Data type: Unsigned16
Dyn. index: -
Func. diagram: 2410
Factory setting
-
SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313
FP
-

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g120d cu250d-2 pn-fSinamics g120d cu240d-2 pnSinamics g120d cu240d-2 pn-fSinamics g120d cu250d-2 dp-f

Table of Contents