p2626
BI: EPOS traversing block selection bit 1 / Trav_blk sel bit 1
CU250D-2_PN_F
Access level: 1
CU250D-2_DP_F
Can be changed: T
Unit group: -
Min
-
Description:
Sets the signal source to select the traversing block, bit 1.
Dependency:
Binector inputs p2625, p2626, p2627 and p2628 are used to select one of the maximum of 16 traversing blocks.
Refer to: p2625, p2627, p2628
p2627
BI: EPOS traversing block selection bit 2 / Trav_blk sel bit 2
CU250D-2_PN_F
Access level: 1
CU250D-2_DP_F
Can be changed: T
Unit group: -
Min
-
Description:
Sets the signal source to select the traversing block, bit 2.
Dependency:
Binector inputs p2625, p2626, p2627 and p2628 are used to select one of the maximum of 16 traversing blocks.
Refer to: p2625, p2626, p2628
p2628
BI: EPOS traversing block selection bit 3 / Trav_blk sel bit 3
CU250D-2_PN_F
Access level: 1
CU250D-2_DP_F
Can be changed: T
Unit group: -
Min
-
Description:
Sets the signal source to select the traversing block, bit 3.
Dependency:
Binector inputs p2625, p2626, p2627 and p2628 are used to select one of the maximum of 16 traversing blocks.
Refer to: p2625, p2626, p2627
p2631
BI: EPOS activate traversing task (0 -> 1) / Trav_task act
CU250D-2_PN_F
Access level: 1
CU250D-2_DP_F
Can be changed: T
Unit group: -
Min
-
Description:
Sets the signal source for "activating traversing task".
BI: p2631 = 0/1 signal
The traversing task, selected using BI: p2625 ... p2630, is started.
Dependency:
Refer to: p2625, p2626, p2627, p2628, p2640, p2641
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
To start a traversing block, the axis must be referenced (r2684.11 = 1).
The status signal r2684.12 = 0/1 signal is used for acknowledgment.
A traversing task can be influenced using the following signals:
- intermediate stop via BI: p2640.
- reject traversing task via BI: p2641.
SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
2 Parameters
2.2 List of parameters
Data type: U32 / Binary
Dyn. index: -
Func. diagram: 3616, 3640
Factory setting
0
Data type: U32 / Binary
Dyn. index: -
Func. diagram: 3616, 3640
Factory setting
0
Data type: U32 / Binary
Dyn. index: -
Func. diagram: 3616, 3640
Factory setting
0
Data type: U32 / Binary
Dyn. index: -
Func. diagram: 3616, 3625
Factory setting
0