Siemens SINAMICS G120D CU240D-2 DP Manual page 260

Sinamics g120d cu240d-2 series; sinamics g120d cu250d-2 series
Hide thumbs Also See for SINAMICS G120D CU240D-2 DP:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
Index:
[0] = Phase U
[1] = Phase V
[2] = Phase W
r1919[0...2]
Identified stator inductance 4 / L_stator 4 ident
Access level: 4
Can be changed: -
Unit group: -
Min
- [mH]
Description:
Displays the stator inductance identified for the 4th point of the saturation characteristic.
Index:
[0] = Phase U
[1] = Phase V
[2] = Phase W
r1925[0...2]
Identified threshold voltage / U_threshold ident
Access level: 4
Can be changed: -
Unit group: -
Min
- [Vrms]
Description:
Displays the identified IGBT threshold voltage.
Index:
[0] = Phase U
[1] = Phase V
[2] = Phase W
r1926[0...2]
Identified effective valve lockout time / t_lock_valve id
Access level: 4
Can be changed: -
Unit group: -
Min
- [µs]
Description:
Displays the identified effective valve lockout time.
Index:
[0] = Phase U
[1] = Phase V
[2] = Phase W
r1927[0...2]
Identified rotor resistance / R_rotor ident
Access level: 4
Can be changed: -
Unit group: -
Min
- [ohm]
Description:
Displays identified rotor resistance (on separately excited synchronous motors: damping resistance).
Index:
[0] = Phase U
[1] = Phase V
[2] = Phase W
p1959[0...n]
Rotating measurement configuration / Rot meas config
Access level: 3
Can be changed: T
Unit group: -
Min
-
Description:
Sets the configuration of the rotating measurement.
260
Calculated: -
Scaling: -
Unit selection: -
Max
- [mH]
Calculated: -
Scaling: -
Unit selection: -
Max
- [Vrms]
Calculated: -
Scaling: -
Unit selection: -
Max
- [µs]
Calculated: -
Scaling: -
Unit selection: -
Max
- [ohm]
Calculated: p0340 = 1
Scaling: -
Unit selection: -
Max
-
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: -
Factory setting
- [mH]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: -
Factory setting
- [Vrms]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: -
Factory setting
- [µs]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: -
Factory setting
- [ohm]
Data type: Unsigned16
Dyn. index: DDS, p0180
Func. diagram: -
Factory setting
0000 0000 0001 1111 bin