Siemens SINAMICS G120D CU240D-2 DP Manual page 746

Sinamics g120d cu240d-2 series; sinamics g120d cu250d-2 series
Hide thumbs Also See for SINAMICS G120D CU240D-2 DP:
Table of Contents

Advertisement

n_set before filt. [rpm]
[6030.2]
r0060
n_act [rpm]
[4715.6]
r0063
[0]
f_outp [Hz]
[6730.4]
r0066
[6731.4]
U_output [Vrms]
[6730.4]
r0072
[6731.4]
Vdc act val [V]
[6730.1]
r0070
[6731.1]
I_act abs val [Arms]
[6714.8]
r0068
[0]
Cos phi act
U_output [Vrms]
<1> [6730.1] r0087
r0072
<1> [6730.4]
<1>
For induction motors.
<2>
For synchronous motors.
1
2
Vector control
Display signals
n_set smth [rpm]
100 ms
r0020
n_act smooth [rpm]
r0021
100 ms
n_act rpm smooth [rpm]
r0022
Disp_val T_smooth
p0045
n_act [rpm]
r0063[1]
f_outp smooth [Hz]
100 ms
r0024
U_outp smooth [Vrms]
r0025
100 ms
Vdc smooth [V]
r0026
100 ms
I_act abs val smth [Arms]
r0027
300 ms
Disp_val T_smooth
p0045
I_act abs val [Arms]
r0068
[1]
3
P_act [kW]
r0082
[2]
3
4
Mod_depth [%]
[6730.4]
r0074
[6731.4]
Id_act [Arms]
[6714.8]
r0076
Iq_act [Arms]
[6714.8]
r0078
<1> [6730.1]
M
<2> [6721.8]
Iq
n_act [rpm]
r0063
[0]
M_act [Nm]
[6799.8]
r0080
[0]
P_act [kW]
[6799.8]
r0082
[0]
Cos phi act
[6730.1]
r0087
[6731.1]
5
6
Function diagram
fp_6799_97_04.vsd
SINAMICS G120D
09.12.2015
V4.7.6
Mod_depth smth [%]
100 ms
r0028
Id_act smooth [Arms]
300 ms
r0029
Iq_act smooth [Arms]
300 ms
r0030
M_act [Nm]
[6799.6]
r0080
[0]
[8021.1]
Disp_val T_smooth
p0045
M_act [Nm]
r0080
[1]
[8021.1]
P_act [kW]
r0082
[0]
[6799.6]
Disp_val T_smooth
p0045
P_act [kW]
r0082
[1]
M_act smooth [Nm]
100 ms
r0031
P_actv_act smth [kW]
r0032
100 ms
Cos phi smooth
300 ms
r0038
7
8
- 6799 -

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g120d cu250d-2 pn-fSinamics g120d cu240d-2 pnSinamics g120d cu240d-2 pn-fSinamics g120d cu250d-2 dp-f