r3930[0...4]
Power unit EEPROM characteristics / PU characteristics
Access level: 3
Can be changed: -
Unit group: -
Min
-
Description:
Displays the characteristics (A5E number and versions) of the power unit.
[0]: A5E number xxxx (A5Exxxxyyyy)
[1]: A5E number yyyy (A5Exxxxyyyy)
[2]: File version (logistic)
[3]: File version (fixed data)
[4]: File version (calib data)
p3950
Service parameter / Serv par
Access level: 3
Can be changed: C, U, T
Unit group: -
Min
-
Description:
For service personnel only.
r3960[0...1]
Control Unit temperature measured / CU temp measured
Access level: 3
Can be changed: -
Unit group: -
Min
- [°C]
Description:
Displays the measured Control Unit temperature.
An appropriate message is output when 87 °C is exceeded.
Index:
[0] = Actual measured value
[1] = Maximum measured value
Dependency:
Refer to: A01009
Note:
The value of -200 indicates that there is no measuring signal.
For r3960[0]:
Displays the currently measured Control Unit temperature.
For r3960[1]:
Displays the highest measured Control Unit temperature. This value is saved on the module in a non-volatile fashion.
r3974
Drive unit status word / Drv_unit ZSW
Access level: 1
Can be changed: -
Unit group: -
Min
-
Description:
Displays the status word for the drive unit.
Bit field:
Bit
00
01
02
SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313
Signal name
Software reset active
Writing of parameters disabled as
parameter save in progress
Writing of parameters disabled as macro is
running
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: p2006
Unit selection: -
Max
- [°C]
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Yes
Yes
Yes
2 Parameters
2.2 List of parameters
Data type: Unsigned16
Dyn. index: -
Func. diagram: -
Factory setting
-
Data type: Unsigned16
Dyn. index: -
Func. diagram: -
Factory setting
-
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: -
Factory setting
- [°C]
Data type: Unsigned32
Dyn. index: -
Func. diagram: -
Factory setting
-
0 signal
No
No
No