Siemens SINAMICS G120D CU240D-2 DP Manual page 575

Sinamics g120d cu240d-2 series; sinamics g120d cu250d-2 series
Hide thumbs Also See for SINAMICS G120D CU240D-2 DP:
Table of Contents

Advertisement

p2080[0...15]
p2081[0...15]
p2082[0...15]
p2083[0...15]
p2084[0...15]
p2103[0...n]
p2104[0...n]
p2105[0...n]
p2106[0...n]
p2107[0...n]
p2108[0...n]
p2112[0...n]
p2116[0...n]
p2117[0...n]
p2144[0...n]
p2148[0...n]
p2200[0...n]
p2220[0...n]
p2221[0...n]
p2222[0...n]
p2223[0...n]
p2235[0...n]
p2236[0...n]
p2286[0...n]
p2290[0...n]
p2508[0...3]
p2509[0...3]
p2510[0...3]
p2511[0...3]
p2512[0...3]
p2514[0...3]
p2549
p2550
p2551
p2552
p2553
p2554
p2568
p2569
p2570
p2575
p2577
p2582
p2589
p2590
p2591
p2595
p2596
p2597
p2604
p2612
p2613
p2614
p2625
p2626
SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313
BI: Binector-connector converter status word 1 / Bin/con ZSW1
BI: Binector-connector converter status word 2 / Bin/con ZSW2
BI: Binector-connector converter status word 3 / Bin/con ZSW3
BI: Binector-connector converter status word 4 / Bin/con ZSW4
BI: Binector-connector converter status word 5 / Bin/con ZSW5
BI: 1st acknowledge faults / 1st acknowledge
BI: 2nd acknowledge faults / 2nd acknowledge
BI: 3rd acknowledge faults / 3rd acknowledge
BI: External fault 1 / External fault 1
BI: External fault 2 / External fault 2
BI: External fault 3 / External fault 3
BI: External alarm 1 / External alarm 1
BI: External alarm 2 / External alarm 2
BI: External alarm 3 / External alarm 3
BI: Motor stall monitoring enable (negated) / Mot stall enab neg
BI: RFG active / RFG active
BI: Technology controller enable / Tec_ctrl enable
BI: Technology controller fixed value selection bit 0 / Tec_ctrl sel bit 0
BI: Technology controller fixed value selection bit 1 / Tec_ctrl sel bit 1
BI: Technology controller fixed value selection bit 2 / Tec_ctrl sel bit 2
BI: Technology controller fixed value selection bit 3 / Tec_ctrl sel bit 3
BI: Technology controller motorized potentiometer raise setpoint / Tec_ctrl mop raise
BI: Technology controller motorized potentiometer lower setpoint / Tec_ctrl mop lower
BI: Hold technology controller integrator / Tec_ctr integ hold
BI: Technology controller limiting enable / Tec_ctrl lim enab
BI: LR activate reference mark search / Ref_mark act
BI: LR activate measuring probe evaluation / MT_eval act
BI: LR selecting measuring probe evaluation / MT_eval select
BI: LR measuring probe evaluation edge / MT_eval edge
BI: LR pos. actual value preprocessing activate corr. value (edge) / ActVal_prepCorrAct
BI: LR activate position actual value setting / s_act setting act
BI: LR enable 1 / Enable 1
BI: LR enable 2 / Enable 2
BI: LR setpoint signal fixed / Mess setp fixed
BI: LR signal travel to fixed stop active / Signal TfS act
BI: LR signal fixed stop reached / Signal fixed stop
BI: LR signal traversing command active / Sig trav_cmnd act
BI: EPOS STOP cam activation / STOP cam act
BI: EPOS STOP cam minus / STOP cam minus
BI: EPOS STOP cam plus / STOP cam plus
BI: EPOS jerk limiting activation / Jerk limit act
BI: EPOS modulo correction activation / Modulo corr act
BI: EPOS software limit switch activation / SW lim sw act
BI: EPOS jog 1 signal source / Jog 1 S_src
BI: EPOS jog 2 signal source / Jog 2 S_src
BI: EPOS jogging incremental / Jog incr
BI: EPOS referencing start / Ref start
BI: EPOS set reference point / Set ref_pt
BI: EPOS referencing type selection / Ref_typ select
BI: EPOS search for reference start direction / Srch for ref dir
BI: EPOS search for reference reference cam / Ref_cam
BI: EPOS search for reference reversing cam minus / Rev minus
BI: EPOS search for reference reversing cam plus / Rev plus
BI: EPOS traversing block selection bit 0 / Trav_blk sel bit 0
BI: EPOS traversing block selection bit 1 / Trav_blk sel bit 1
2.4 BICO parameters (connectors/binectors)
2 Parameters
575

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g120d cu250d-2 pn-fSinamics g120d cu240d-2 pnSinamics g120d cu240d-2 pn-fSinamics g120d cu250d-2 dp-f

Table of Contents