Siemens SINAMICS G120D CU240D-2 DP Manual page 54

Sinamics g120d cu240d-2 series; sinamics g120d cu250d-2 series
Hide thumbs Also See for SINAMICS G120D CU240D-2 DP:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
r0231[0...1]
Power cable length maximum / Cable length max
Access level: 3
Can be changed: -
Unit group: -
Min
- [m]
Description:
Displays the maximum permissible cable lengths between the drive unit and motor.
Index:
[0] = Unshielded
[1] = Shielded
Note:
The display value is used to provide information for service and maintenance.
p0233
Power unit motor reactor / PU mot reactor
Access level: 2
Can be changed: C(2), U, T
Unit group: -
Min
0.000 [mH]
Description:
Enter the inductance of a filter connected at the power unit output.
Dependency:
This parameter is automatically pre-set when you select a filter via p0230 if a SIEMENS filter is defined for the power
unit.
Refer to: p0230
Note:
When exiting the quick commissioning using p3900 = 1, the parameter value is set to the value of the defined
SIEMENS filter or to zero. For this reason, the parameter value of a third-party filter only has to be entered outside
the commissioning phase (p0010 = 0) and then the controller calculation (p0340 = 3) is carried out.
The parameter cannot be changed if the power unit has an internal sine-wave filter.
p0234
Power unit sine-wave filter capacitance / PU sine filter C
Access level: 2
Can be changed: C(2), U, T
Unit group: -
Min
0.000 [µF]
Description:
Enters the capacitance of a sine-wave filter connected at the power unit output.
Dependency:
This parameter is automatically pre-set when you select a filter via p0230 if a SIEMENS filter is defined for the power
unit.
Refer to: p0230
Note:
The parameter value includes the sum of all of the capacitances of a phase connected in series (phase - ground).
When exiting the quick commissioning using p3900 = 1, the parameter value is set to the value of the defined
SIEMENS filter or to zero. For this reason, the parameter value of a third-party filter only has to be entered outside
the commissioning phase (p0010 = 0).
The parameter cannot be changed if the power unit has an internal sine-wave filter.
r0238
Internal power unit resistance / PU R internal
Access level: 3
Can be changed: -
Unit group: -
Min
- [ohm]
Description:
Displays the internal resistance of the power unit (IGBT and line resistance).
54
Calculated: -
Scaling: -
Unit selection: -
Max
- [m]
Calculated: -
Scaling: -
Unit selection: -
Max
1000.000 [mH]
Calculated: -
Scaling: -
Unit selection: -
Max
1000.000 [µF]
Calculated: -
Scaling: -
Unit selection: -
Max
- [ohm]
Data type: Unsigned16
Dyn. index: -
Func. diagram: -
Factory setting
- [m]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: -
Factory setting
0.000 [mH]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: -
Factory setting
0.000 [µF]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: -
Factory setting
- [ohm]
SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313