r0052.5 Quick stop active (OFF3)
r0052.6 Switching-on inhibited active
r0052.7 Alarm present
r0052.9 Control request
r0052.14 Motor rotates forwards
r0053.0 DC braking active
r0053.1 n_act > p2167 (n_off)
r0053.2 n_act <= p1080 (n_min)
r0053.3 I_act > p2170
r0053.4 n_act > p2155
r0053.5 n_act <= p2155
r0053.6 n_act >= n_set
r0053.10 Technology controller output at the lower limit
r0053.11 Technology controller output at the upper limit
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
DO: Digital Output
r0747
CU digital outputs status / CU DO status
Access level: 3
Can be changed: -
Unit group: -
Min
-
Description:
Displays the status of digital outputs.
Bit field:
Bit
00
01
Note:
DO: Digital Output
T: Terminal
Relay output: NO = normally open, NC = normally closed
Inversion using p0748 has been taken into account.
p0748
CU invert digital outputs / CU DO inv
Access level: 3
Can be changed: U, T
Unit group: -
Min
-
Description:
Setting to invert the signals at the digital outputs.
Bit field:
Bit
00
01
Note:
DO: Digital Output
T: Terminal
Relay output: NO = normally open, NC = normally closed
r0751.0...9
BO: CU analog inputs status word / CU AI status word
CU240D-2_DP
Access level: 3
CU240D-2_PN
Can be changed: -
CU240D-2_DP_F
Unit group: -
CU240D-2_PN_F
Min
-
Description:
Display and binector output for the status of the analog inputs.
SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313
Signal name
DO 0 (NO: X05.4)
DO 1 (NO: X05.2)
Signal name
DO 0 (NO: X05.4)
DO 1 (NO: X05.2)
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
High
High
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Inverted
Inverted
Calculated: -
Scaling: -
Unit selection: -
Max
-
2 Parameters
2.2 List of parameters
Data type: Unsigned32
Dyn. index: -
Func. diagram: 2130, 2131, 2132,
2133
Factory setting
-
0 signal
Low
Low
Data type: Unsigned32
Dyn. index: -
Func. diagram: 2241
Factory setting
0000 bin
0 signal
Not inverted
Not inverted
Data type: Unsigned16
Dyn. index: -
Func. diagram: 9566, 9568
Factory setting
-