Procedure:
Setting p9400 = 2 results in a value of 3
--> The memory card can be removed safely. After removal the value sets itself to 0 automatically.
Setting p9400 = 2 results in a value of 100
--> The memory card cannot be removed safely. Removal may destroy the file system on the memory card. It may be
necessary to set p9400 = 2 again.
Value:
0:
1:
2:
3:
100:
Dependency:
Refer to: r9401
Notice:
Removing the memory card without a request (p9400 = 2) and confirmation (p9400 = 3) may destroy the file system
on the memory card. The memory card will then no longer work properly and must be replaced.
Note:
The status when the memory card is being "removed safely" is shown in r9401.
For value = 0, 1, 3, 100:
These values can only be displayed, not set.
r9401
Safely remove memory card status / Mem_card rem stat
Access level: 2
Can be changed: -
Unit group: -
Min
-
Description:
Displays the status of the memory card.
Bit field:
Bit
00
01
02
03
Dependency:
Refer to: p9400
Note:
For bit 01, 00:
Bit 1/0 = 0/0: No memory card inserted (corresponds to p9400 = 0).
Bit 1/0 = 0/1: "Safe removal" possible (corresponds to p9400 = 3).
Bit 1/0 = 1/0: Status not possible.
Bit 1/0 = 1/1: Memory card inserted (corresponds to p9400 = 1, 2, 100).
For bit 02, 00:
Bit 2/0 = 0/0: No memory card inserted.
Bit 2/0 = 0/1: Memory card inserted, but not a SIEMENS memory card.
Bit 2/0 = 1/0: Status not possible.
Bit 2/0 = 1/1: SIEMENS memory card inserted.
r9406[0...19]
PS file parameter number parameter not transferred / PS par_no n transf
Access level: 4
Can be changed: -
Unit group: -
Min
-
Description:
Displays the parameters that were not able to be transferred when reading the parameter back-up files (PS files)
from the non-volatile memory (e.g. memory card).
SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313
No memory card inserted
Memory card inserted
Request "safe removal" of the memory card
"Safe removal" possible
"Safe removal" not possible due to access
Signal name
Memory card inserted
Memory card activated
SIEMENS memory card
Memory card as USB data storage medium
from the PC used
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Calculated: -
Scaling: -
Unit selection: -
Max
-
2 Parameters
2.2 List of parameters
Data type: Unsigned16
Dyn. index: -
Func. diagram: -
Factory setting
-
0 signal
No
No
No
No
Data type: Unsigned16
Dyn. index: -
Func. diagram: -
Factory setting
-