p2589
BI: EPOS jog 1 signal source / Jog 1 S_src
CU250D-2_PN_F
Access level: 1
CU250D-2_DP_F
Can be changed: T
Unit group: -
Min
-
Description:
Sets the signal source for jog 1.
Dependency:
When jogging, the axis is accelerated or braked with the maximum acceleration/deceleration (p2572/p2573).
BI: p2591 = 0 signal
The axis endlessly moves with the setpoint velocity, jog 1 (p2585).
BI: p2591 = 1 signal
The axis traverses through a parameterized distance (p2585) with the setpoint velocity, jog 1 (p2587).
Refer to: p2572, p2573, p2585, p2587, p2591
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
p2590
BI: EPOS jog 2 signal source / Jog 2 S_src
CU250D-2_PN_F
Access level: 1
CU250D-2_DP_F
Can be changed: T
Unit group: -
Min
-
Description:
Sets the signal source for jog 2.
Dependency:
When jogging, the axis is accelerated or braked with the maximum acceleration/deceleration (p2572/p2573).
BI: p2591 = 0 signal
The axis endlessly moves with the setpoint velocity, jog 2 (p2586).
BI: p2591 = 1 signal
The axis traverses through a parameterized distance (p2586) with the setpoint velocity, jog 2 (p2588).
Refer to: p2572, p2573, p2586, p2588, p2591
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
p2591
BI: EPOS jogging incremental / Jog incr
CU250D-2_PN_F
Access level: 1
CU250D-2_DP_F
Can be changed: T
Unit group: -
Min
-
Description:
Sets the signal source for jogging incremental.
Dependency:
Refer to: p2585, p2586, p2587, p2588, p2589, p2590
p2593
CI: EPOS LU/revolution LU/mm / LU/rev LU/mm
CU250D-2_PN_F
Access level: 3
CU250D-2_DP_F
Can be changed: T
Unit group: -
Min
-
Description:
Sets the signal source for the reference of the internal length units LU to motor revolution for rotary encoders and to
mm for linear encoders.
Dependency:
Refer to: p0404, r2524, p2594
Note:
The signal value is used to convert the length unit to the speed or velocity setpoint.
SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
2 Parameters
2.2 List of parameters
Data type: U32 / Binary
Dyn. index: -
Func. diagram: 3610, 3625
Factory setting
722.3
Data type: U32 / Binary
Dyn. index: -
Func. diagram: 3610, 3625
Factory setting
722.4
Data type: U32 / Binary
Dyn. index: -
Func. diagram: 3610
Factory setting
722.5
Data type: U32 / FloatingPoint32
Dyn. index: -
Func. diagram: 3630
Factory setting
2524[0]
355