Siemens SINAMICS G120D CU240D-2 DP Manual page 47

Sinamics g120d cu240d-2 series; sinamics g120d cu250d-2 series
Hide thumbs Also See for SINAMICS G120D CU240D-2 DP:
Table of Contents

Advertisement

r0084[0...1]
CO: Flux actual value / Flux act val
Access level: 4
Can be changed: -
Unit group: -
Min
- [%]
Description:
Displays the flux actual value.
Index:
[0] = Unsmoothed
[1] = Smoothed
r0087
CO: Actual power factor / Cos phi act
Access level: 3
Can be changed: -
Unit group: -
Min
-
Description:
Displays the actual active power factor.
This value refers to the electrical power of the basic fundamental signals at the output terminals of the converter.
r0089[0...2]
Actual phase voltage / U_phase act val
Access level: 4
Can be changed: -
Unit group: 5_3
Min
- [V]
Description:
Displays the actual phase voltage.
Index:
[0] = Phase U
[1] = Phase V
[2] = Phase W
Note:
The values are determined from the transistor switch-on duration.
r0094
CO: Transformation angle / Transformat_angle
Access level: 3
Can be changed: -
Unit group: -
Min
- [°]
Description:
Displays the transformation angle.
Dependency:
Refer to: r1778
Note:
The transformation angle corresponds to the electrical commutation angle.
p0100
IEC/NEMA mot stds / IEC/NEMA mot stds
Access level: 1
Can be changed: C(1)
Unit group: -
Min
0
Description:
Defines whether the motor and drive converter power settings (e.g. rated motor power, p0307) are expressed in [kW]
or [hp].
Depending on the selection, the rated motor frequency (p0310) is either set to 50 Hz or 60 Hz.
For p0100 = 0, 2, the following applies: The power factor (p0308) should be parameterized.
For p0100 = 1, the following applies: The efficiency (p0309) should be parameterized.
SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313
Calculated: -
Scaling: PERCENT
Unit selection: -
Max
- [%]
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: p2001
Unit selection: p0505
Max
- [V]
Calculated: -
Scaling: p2005
Unit selection: -
Max
- [°]
Calculated: -
Scaling: -
Unit selection: -
Max
2
2 Parameters
2.2 List of parameters
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 6730, 6731
Factory setting
- [%]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: -
Factory setting
-
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 6719
Factory setting
- [V]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: -
Factory setting
- [°]
Data type: Integer16
Dyn. index: -
Func. diagram: -
Factory setting
0