Siemens SINAMICS G120D CU240D-2 DP Manual page 462

Sinamics g120d cu240d-2 series; sinamics g120d cu250d-2 series
Hide thumbs Also See for SINAMICS G120D CU240D-2 DP:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
r9708[0...5]
SI Motion diagnostics safe position / SI mtn safe pos
CU240D-2_DP_F
Access level: 3
CU240D-2_PN_F
Can be changed: -
CU250D-2_PN_F
Unit group: -
CU250D-2_DP_F
Min
- [°]
Description:
Displays the actual load-side actual values of both monitoring channels and their difference.
Index:
[0] = Load-side actual value on the CU
[1] = Load-side actual value on the second channel
[2] = Load-side actual value difference CU - second channel
[3] = Load-side max. actual value difference CU - second channel
[4] = Load-side actual value as safe position via PROFIsafe
[5] = Load-side additional actual value difference CU - second channel
Dependency:
Refer to: r9713
Note:
For index 0:
The display of the load-side position actual value on processor 1 is updated in the monitoring clock cycle.
For index 1:
The display of the load-side position actual value on processor 2 is updated in the CDC clock cycle (r9724) and
delayed by one CDC clock cycle.
For index 2:
The difference between the load-side position actual value on processor 1 and load-side position actual value on
processor 2 is updated in the CDC clock cycle (r9724) and delayed by one CDC clock cycle.
For index 3:
The maximum difference between the load-side position actual value on processor 1 and the load-side position
actual value on processor 2.
For index 4:
The content corresponds to the value in index 0.
CDC: Crosswise Data Comparison
r9710[0...1]
SI Motion diagnostics result list 1 / SI Mtn res_list 1
CU240D-2_DP_F
Access level: 3
CU240D-2_PN_F
Can be changed: -
CU250D-2_PN_F
Unit group: -
CU250D-2_DP_F
Min
-
Description:
Displays result list 1 that, for the crosswise data comparison between the monitoring channels, led to the fault.
Index:
[0] = Result list processor 2
[1] = Result list processor 1
Bit field:
Bit
06
07
08
09
10
11
12
13
16
17
18
19
20
21
Dependency:
Refer to: C01711
Note:
SAM: Safe Acceleration Monitor (safe acceleration monitoring)
SBR: Safe Brake Ramp (safe brake ramp monitoring)
SLS: Safely Limited Speed
462
Signal name
Actual value > upper limit SLS1
Actual value > lower limit SLS1
Actual value > upper limit SLS2
Actual value > lower limit SLS2
Actual value > upper limit SLS3
Actual value > lower limit SLS3
Actual value > upper limit SLS4
Actual value > lower limit SLS4
Actual value > upper limit SAM/SBR
Actual value > lower limit SAM/SBR
Actual value > upper limit SDI positive
Actual value > lower limit SDI positive
Actual value > upper limit SDI negative
Actual value > lower limit SDI negative
Calculated: -
Scaling: -
Unit selection: -
Max
- [°]
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 2822, 2836
Factory setting
- [°]
Data type: Unsigned32
Dyn. index: -
Func. diagram: -
Factory setting
-
0 signal
No
No
No
No
No
No
No
No
No
No
No
No
No
No
SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313
FP
-
-
-
-
-
-
-
-
-
-
-
-
-
-

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for: