Siemens SINAMICS G120D CU240D-2 DP Manual page 534

Sinamics g120d cu240d-2 series; sinamics g120d cu250d-2 series
Hide thumbs Also See for SINAMICS G120D CU240D-2 DP:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
p20229
LIM 0 upper limit value LU / LIM 0 upper lim LU
CU240D-2_DP
Access level: 3
CU240D-2_PN
Can be changed: T
CU240D-2_DP_F
Unit group: -
CU240D-2_PN_F
Min
-340.28235E36
Description:
Setting parameter for the upper limit value LU of instance LIM 0 of the limiter.
p20230
LIM 0 lower limit value LL / LIM 0 lower lim LL
CU240D-2_DP
Access level: 3
CU240D-2_PN
Can be changed: T
CU240D-2_DP_F
Unit group: -
CU240D-2_PN_F
Min
-340.28235E36
Description:
Setting parameter for the lower limit value LL of instance LIM 0 of the limiter.
r20231
CO: LIM 0 output Y / LIM 0 output Y
CU240D-2_DP
Access level: 3
CU240D-2_PN
Can be changed: -
CU240D-2_DP_F
Unit group: -
CU240D-2_PN_F
Min
-
Description:
Display parameter for the limited output quantity Y of instance LIM 0 of the limiter.
r20232
BO: LIM 0 input quantity at the upper limit QU / LIM 0 QU
CU240D-2_DP
Access level: 3
CU240D-2_PN
Can be changed: -
CU240D-2_DP_F
Unit group: -
CU240D-2_PN_F
Min
-
Description:
Display parameter of instance LIM 0 of limiter QU (upper limit reached), i.e. QU = 1 for X >= LU.
r20233
BO: LIM 0 input quantity at the lower limit QL / LIM 0 QL
CU240D-2_DP
Access level: 3
CU240D-2_PN
Can be changed: -
CU240D-2_DP_F
Unit group: -
CU240D-2_PN_F
Min
-
Description:
Display parameter of instance LIM 0 of limiter QL (lower limit reached), i.e. QL = 1 for X <= LL.
p20234
LIM 0 run-time group / LIM 0 RTG
CU240D-2_DP
Access level: 3
CU240D-2_PN
Can be changed: T
CU240D-2_DP_F
Unit group: -
CU240D-2_PN_F
Min
5
Description:
Setting parameter for the run-time group in which instance LIM 0 of the limiter is to be called.
Value:
5:
6:
9999: Do not calculate
534
Run-time group 5
Run-time group 6
Calculated: -
Scaling: -
Unit selection: -
Max
340.28235E36
Calculated: -
Scaling: -
Unit selection: -
Max
340.28235E36
Calculated: -
Scaling: PERCENT
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
9999
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 7260
Factory setting
0.0000
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 7260
Factory setting
0.0000
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 7260
Factory setting
-
Data type: Unsigned32
Dyn. index: -
Func. diagram: 7260
Factory setting
-
Data type: Unsigned32
Dyn. index: -
Func. diagram: 7260
Factory setting
-
Data type: Integer16
Dyn. index: -
Func. diagram: 7260
Factory setting
9999
SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g120d cu250d-2 pn-fSinamics g120d cu240d-2 pnSinamics g120d cu240d-2 pn-fSinamics g120d cu250d-2 dp-f

Table of Contents