2 Parameters
2.2 List of parameters
p1825
Converter valve threshold voltage / Threshold voltage
Access level: 4
Can be changed: U, T
Unit group: -
Min
0.0 [Vrms]
Description:
Sets the threshold voltage drop of the valves (power semiconductor devices) to be compensated.
Note:
The value is automatically calculated in the motor data identification routine.
p1828
Compensation valve lockout time phase U / Comp t_lock ph U
Access level: 4
Can be changed: U, T
Unit group: -
Min
0.00 [µs]
Description:
Sets the valve lockout time to compensate for phase U.
Note:
The value is automatically calculated in the motor data identification routine.
p1829
Compensation valve lockout time phase V / Comp t_lock ph V
Access level: 4
Can be changed: U, T
Unit group: -
Min
0.00 [µs]
Description:
Sets the valve lockout time to compensate for phase V.
p1830
Compensation valve lockout time phase W / Comp t_lock ph W
Access level: 4
Can be changed: U, T
Unit group: -
Min
0.00 [µs]
Description:
Sets the valve lockout time to compensate for phase W.
p1832
Dead time compensation current level / t_dead_comp I_lev
Access level: 4
Can be changed: U, T
Unit group: -
Min
0.0 [Arms]
Description:
Sets the current level for the dead time compensation.
Above the current level, the dead time - resulting from the converter switching delays - is compensated by a
previously calculated constant value. If the relevant phase current setpoint falls below the absolute value defined by
p1832, the corrective value for this phase is continuously reduced.
Dependency:
The factory setting of p1832 is automatically set to 0.02 * rated drive converter current (r0207).
252
Calculated: p0340 = 1
Scaling: -
Unit selection: -
Max
100.0 [Vrms]
Calculated: p0340 = 1
Scaling: -
Unit selection: -
Max
3.99 [µs]
Calculated: p0340 = 1
Scaling: -
Unit selection: -
Max
3.99 [µs]
Calculated: p0340 = 1
Scaling: -
Unit selection: -
Max
3.99 [µs]
Calculated: p0340 = 1
Scaling: -
Unit selection: -
Max
10000.0 [Arms]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: -
Factory setting
0.6 [Vrms]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: -
Factory setting
0.00 [µs]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: -
Factory setting
0.00 [µs]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: -
Factory setting
0.00 [µs]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: -
Factory setting
0.0 [Arms]
SINAMICS G120D