Siemens SINAMICS G120D CU240D-2 DP Manual page 758

Sinamics g120d cu240d-2 series; sinamics g120d cu250d-2 series
Hide thumbs Also See for SINAMICS G120D CU240D-2 DP:
Table of Contents

Advertisement

1
2
Free function blocks - Arithmetic function blocks
AVA 0 ... 1
AVA (absolute value generator)
AVA 0
AVA 0 RTG
5 ... 9999
p20131 (9999)
AVA 0 input X
p20128
X
(0)
AVA 0 RunSeq
0 ... 32000
p20132 (340)
AVA 1
AVA 1 RTG
5 ... 9999
p20136 (9999)
AVA 1 input X
p20133
X
(0)
AVA 1 RunSeq
0 ... 32000
p20137 (350)
3
4
AVA 0 output Y
Y
r20129
AVA 0 input neg SN
SN
r20130
AVA 1 output Y
Y
r20134
AVA 1 input neg SN
SN
r20135
5
6
Function diagram
fp_7224_97_61.vsd
G120D CU240D-2
09.12.2015
V4.7.6
7
8
- 7224 -