X07
X07.1
1L+
X07.2
DI 1
2
DI 1
<2>
X07.3
1M
1
5
3
X07.4
DI 0
4
DI 0
<2>
X07.5
FE
X08
X08.1
1L+
X08.2
DI 3
2
DI 3
<2>
X08.3
1M
1
5
3
X08.4
DI 2
4
DI 2
<2>
X08.5
FE
X09.1
1L+
X09
X09.2
DI 5
2
DI 5
<2>
X09.3
1M
1
5
3
X09.4
DI 4
4
DI 4
<2>
X09.5
FE
X10.1
X10
<1>
X10.2
+10 V OUT
X10.3
AI 0+
1
2
7
X10.4
AI 1+
8
3
6
X10.5
4
5
X10.6
X10.7
0 V
X10.8
<4>
1 U
2
3 W
4
motor holding brake (-)
5 T1 motor (+)
6 motor holding brake (+)
7 V
8 T2 motor (-)
FE
1
2
Input/Output Terminals
Connection overview
CU DI simulation
Simulation for
CU DI t_debounce
p0795
.0...5
p0724
DI 0...DI 5,
r0721.0...5
DI 11...DI 12
0
T
p0796.0...5
1
1 = Simulation on
[2210]
6 Digital inputs
CU DI status inv
r0723
1
r0723
.0
CU DI status
r0722
r0722
24 V
...
...
CU DI status inv
5 V
r0723
1
r0723
.5
CU DI status
r0722
r0722
[2251]
2 Analog inputs
A
CU AI value in % [%]
r0755
D
CU AI value in % [%]
A
r0755
D
[8016]
Thermal monitoring, motor
Mot temp [°C]
A
r0035
D
3
4
CU DI status inv
r0723
1
r0723
.0...5
CU DI status
0
r0722
r0722
.0...5
[2241]
CU DO inv
p0748
CU S_src DO 0
0
p0730
.0
(52.3)
1
1
CU S_src DO 1
0
p0731
(52.7)
1
1
.5
[0]
[1]
<1>
Only for CU240D-2.
<2>
If the Safety Integrated Extended Functions are activated, can also be used as F-DI,
see [2850].
[2]
<3>
If the Safety Integrated Extended Functions are activated, can also be used as F-DO,
see [2853].
<4>
Connection via PM
5
6
fp_2201_97_04.vsd
09.12.2015
2 Digital outputs
<3>
1
24 V
DO 0
X05.4
0 V
0
2M
X05.3
1
24 V
DO 1
0 V
<3>
X05.2
0
FE
X05.5
FE: Functional Earth
7
Function diagram
SINAMICS G120D
V4.7.6
X05
2
1
5
3
4
8
- 2201 -