2 Parameters
2.2 List of parameters
p9651
SI STO debounce time (processor 1) / SI STO t_debou P1
Access level: 3
Can be changed: C(95)
Unit group: -
Min
0.00 [ms]
Description:
Sets the debounce time for the failsafe digital inputs used to control the "STO" function.
The debounce time is rounded to whole milliseconds.
Note:
The debounce time is rounded to whole milliseconds. It specifies the maximum duration of a fault pulse at the fail-
safe digital inputs with no reaction/influence on the selection or deselection of the Safety Basic Functions.
Example:
Debounce time = 1 ms: Fault pulses of 1 ms are filtered; only pulses longer than 2 ms are processed.
Debounce time = 3 ms: Fault pulses of 3 ms are filtered; only pulses longer than 4 ms are processed.
p9659
SI forced checking procedure timer / SI FCP Timer
Access level: 3
Can be changed: C(95)
Unit group: -
Min
0.00 [h]
Description:
Sets the time interval for carrying out the forced checking procedure and testing the Safety switch-off signal paths.
Within the parameterized time, STO must have been de-selected at least once. The monitoring time is reset each
time that STO is de-selected.
Dependency:
Refer to: A01699
Note:
STO: Safe Torque Off
r9660
SI forced checking procedure remaining time / SI frc chk remain
Access level: 3
Can be changed: -
Unit group: -
Min
- [h]
Description:
Displays the time remaining before dynamization and testing of the safety switch-off signal paths (forced checking
procedure).
Dependency:
Refer to: A01699
p9670
SI module identification Control Unit / Module ID CU
Access level: 3
Can be changed: T
Unit group: -
Min
0
Description:
CRC via Node Identifier of the Control Unit.
Note:
CU: Control Unit
p9672
SI module identifier Power Module / Module ID PM
Access level: 3
Can be changed: C(95), T
Unit group: -
Min
0
Description:
CRC via the Node Identifier of a Power Module.
460
Calculated: -
Scaling: -
Unit selection: -
Max
100.00 [ms]
Calculated: -
Scaling: -
Unit selection: -
Max
9000.00 [h]
Calculated: -
Scaling: -
Unit selection: -
Max
- [h]
Calculated: -
Scaling: -
Unit selection: -
Max
4294967295
Calculated: -
Scaling: -
Unit selection: -
Max
4294967295
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: -
Factory setting
1.00 [ms]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 2810
Factory setting
8.00 [h]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: -
Factory setting
- [h]
Data type: Unsigned32
Dyn. index: -
Func. diagram: -
Factory setting
0
Data type: Unsigned32
Dyn. index: -
Func. diagram: -
Factory setting
0
SINAMICS G120D