For bit 00:
Calculation for the constant and linear coefficients of the moment of inertia precontrol is activated. The results are
written to parameters (p5312, p5313, p5314, p5315).
For bit 01:
The moment of inertia precontrol is activated.
The moment of inertia is calculated from the currently measured load torque and the saved coefficients (p5312,
p5313, p5314, p5315).
r5311[0...n]
Moment of inertia precontrol status word / J_prectrl ZSW
Access level: 3
Can be changed: -
Unit group: -
Min
-
Description:
Displays the status word for the moment of inertia precontrol.
Bit field:
Bit
00
01
02
03
04
05
Dependency:
The function module "Moment of inertia estimator" (r0108.10) must be activated for the "Moment of inertia precontrol"
function.
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
Refer to: p5310, p5312, p5313, p5314, p5315
p5312[0...n]
Moment of inertia precontrol linear positive / J_est lin pos
Access level: 3
Can be changed: C(3), U, T
Unit group: -
Min
-340.28235E36 [s^2]
Description:
Setting of the linear coefficients for moment of inertia precontrol in the positive direction when the moment of inertia
estimator is active.
The estimated moment of inertia is obtained according to the following formula:
Moment of inertia (J) = linear coefficient (p5312) * load torque + constant coefficient (p5313)
Dependency:
The function module "Moment of inertia estimator" (r0108.10) must be activated for the "Moment of inertia precontrol"
function.
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
Refer to: p5310, r5311, p5313, p5314, p5315
p5313[0...n]
Moment of inertia precontrol constant positive / J_est const pos
Access level: 3
Can be changed: C(3), U, T
Unit group: 25_1
Min
-340.28235E36 [kgm²]
Description:
Setting of the constant coefficients for moment of inertia precontrol in the positive direction when the moment of
inertia estimator is active.
The estimated moment of inertia is obtained according to the following formula:
Moment of inertia (J) = linear coefficient (p5312) * load torque + constant coefficient (p5313)
SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313
Signal name
New measuring points are available
New parameters being calculated
Moment of inertia precontrol active
Calculation of positive coefficients
completed
Calculation of negative coefficients
completed
Results are being written to parameter
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Calculated: p0340 = 1
Scaling: -
Unit selection: -
Max
340.28235E36 [s^2]
Calculated: p0340 = 1
Scaling: -
Unit selection: p0100
Max
340.28235E36 [kgm²]
2 Parameters
2.2 List of parameters
Data type: Unsigned32
Dyn. index: DDS, p0180
Func. diagram: -
Factory setting
-
0 signal
No
No
No
No
No
No
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: -
Factory setting
0.000000 [s^2]
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: -
Factory setting
0.000000 [kgm²]
FP
-
-
-
-
-
-