2 Parameters
2.2 List of parameters
r0965
PROFIdrive profile number / PD profile number
Access level: 3
Can be changed: -
Unit group: -
Min
-
Description:
Displays the PROFIdrive profile number and profile version.
Constant value = 0329 hex.
Byte 1: Profile number = 03 hex = PROFIdrive profile
Byte 2: Profile version = 29 hex = Version 4.1
Note:
When the parameter is read via PROFIdrive, the Octet String 2 data type applies.
p0969
System runtime relative / t_System relative
Access level: 3
Can be changed: T
Unit group: -
Min
0 [ms]
Description:
Displays the system runtime in ms since the last POWER ON.
Note:
The value in p0969 can only be reset to 0.
The value overflows after approx. 49 days.
When the parameter is read via PROFIdrive, the TimeDifference data type applies.
p0970
Reset drive parameters / Drive par reset
Access level: 1
Can be changed: C(1, 30)
Unit group: -
Min
0
Description:
The parameter is used to initiate the reset of the drive parameters.
Parameters p0100, p0205 are not reset.
The following motor parameters are defined in accordance with the power unit: p0300 ... p0311.
When downloading settings 10, 11, 12, the buffer memory mode is automatically de-activated (p0014 = 0).
Value:
0:
1:
3:
5:
10:
11:
12:
30:
100:
300:
Dependency:
Refer to: F01659
Notice:
After the value has been modified, no further parameter modifications can be made and the status is shown in r3996.
Modifications can be made again when r3996 = 0.
When the buffer memory is active (see p0014), the actual parameters are backed up from RAM to ROM when a
parameter set is loaded (p0970 = 10, 11, 12).
Peculiarities of communication via PROFIBUS DP:
- Communication with Class 1 masters (e.g. S7 controllers) is interrupted.
- Communication with Class 2 masters (e.g. STARTER) is retained.
148
Inactive
Start a parameter reset
Start download of volatile parameters from RAM
Starts a safety parameter reset
Start loading the parameters saved with p0971=10
Start loading the parameters saved with p0971=11
Start loading the parameters saved with p0971=12
Start loading the delivery state saved with p0971=30
Start a BICO interconnection reset
Only Siemens int
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
4294967295 [ms]
Calculated: -
Scaling: -
Unit selection: -
Max
300
Data type: Unsigned16
Dyn. index: -
Func. diagram: -
Factory setting
-
Data type: Unsigned32
Dyn. index: -
Func. diagram: 8050, 8060
Factory setting
0 [ms]
Data type: Unsigned16
Dyn. index: -
Func. diagram: -
Factory setting
0
SINAMICS G120D