2 Parameters
2.2 List of parameters
Dependency:
Refer to: p8980
Note:
Changes only become effective after POWER ON.
The parameter is not influenced by setting the factory setting.
p8991
USB memory access / USB mem acc
Access level: 3
Can be changed: T
Unit group: -
Min
1
Description:
Selects the storage medium for access via the USB mass storage.
Value:
1:
2:
Note:
A change only becomes effective after a POWER ON.
The parameter is not influenced by setting the factory setting.
p8999
USB functionality / USB Fct
Access level: 4
Can be changed: T
Unit group: -
Min
1
Description:
Setting the USB functionality.
Value:
1:
2:
3:
Note:
COMM: Commissioning.
A change only becomes effective after a POWER ON.
The parameter is not influenced by setting the factory setting.
p9301
SI Motion enable safety functions (processor 2) / SI Mtn enable P2
CU240D-2_DP_F
Access level: 3
CU240D-2_PN_F
Can be changed: C(95)
CU250D-2_PN_F
Unit group: -
CU250D-2_DP_F
Min
-
Description:
Sets the enable signals for the safe motion monitoring.
Bit field:
Bit
00
16
17
30
Dependency:
Refer to: p9501
Refer to: F01682, F01683
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note:
For bit 30 = 1, PROFIsafe telegram 900 must be configured in the F host.
A change only becomes effective after a POWER ON.
F-DI: Failsafe Digital Input
SDI: Safe Direction (safe motion direction)
SLS: Safely Limited Speed
SSM: Safe Speed Monitor (safety-relevant feedback signal from the velocity monitoring)
434
Memory card
Flash r/w internal
USS commissioning via the virtual COM port
Only memory access
USB commissioning and memory access
Signal name
Enable SI Motion
Enable SSM hysteresis and filtering
Enable SDI
Enable F-DI in PROFIsafe telegram 900
Calculated: -
Scaling: -
Unit selection: -
Max
2
Calculated: -
Scaling: -
Unit selection: -
Max
3
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Enable
Enable
Enable
Enable
Data type: Integer16
Dyn. index: -
Func. diagram: -
Factory setting
1
Data type: Integer16
Dyn. index: -
Func. diagram: -
Factory setting
3
Data type: Unsigned32
Dyn. index: -
Func. diagram: -
Factory setting
0000 0000 0000 0000 0000 0000 0000
0000 bin
0 signal
Inhibit
Inhibit
Inhibit
Inhibit
SINAMICS G120D