p0544[0...n]
Load gearbox overall ratio (absolute value) numerator / Load grbx ratio N
Access level: 3
Can be changed: T
Unit group: -
Min
0
Description:
Sets the numerator for the overall ratio of the load gearbox.
p0545[0...n]
Load gearbox overall ratio (absolute value) denominator / Load grbx ratio D
Access level: 3
Can be changed: T
Unit group: -
Min
0
Description:
Sets the denominator for the overall ratio of the load gearbox.
p0546[0...n]
Load gearbox output direction of rotation inversion / Load grbx outp inv
Access level: 3
Can be changed: T
Unit group: -
Min
0
Description:
Sets the inversion for the direction of rotation of the load gearbox.
p0550[0...n]
Brake type / Brake type
Access level: 3
Can be changed: T
Unit group: -
Min
0
Description:
Sets the brake version.
p0551[0...n]
Brake code number / Brake code no.
Access level: 3
Can be changed: T
Unit group: -
Min
0
Description:
Display and setting the code number of the brake.
p0552[0...n]
Maximum brake speed / Brake n_max
Access level: 3
Can be changed: T
Unit group: -
Min
0 [rpm]
Description:
Sets the maximum brake speed.
104
Calculated: -
Scaling: -
Unit selection: -
Max
2147483647
Calculated: -
Scaling: -
Unit selection: -
Max
2147483647
Calculated: -
Scaling: -
Unit selection: -
Max
2147483647
Calculated: -
Scaling: -
Unit selection: -
Max
65535
Calculated: -
Scaling: -
Unit selection: -
Max
65535
Calculated: -
Scaling: -
Unit selection: -
Max
340.28235E36 [rpm]
Data type: Integer32
Dyn. index: MDS
Func. diagram: -
Factory setting
0
Data type: Integer32
Dyn. index: MDS
Func. diagram: -
Factory setting
0
Data type: Integer32
Dyn. index: MDS
Func. diagram: -
Factory setting
0
Data type: Unsigned16
Dyn. index: MDS
Func. diagram: -
Factory setting
0
Data type: Unsigned16
Dyn. index: MDS
Func. diagram: -
Factory setting
0
Data type: FloatingPoint32
Dyn. index: MDS
Func. diagram: -
Factory setting
0 [rpm]