Siemens SINAMICS G120D CU240D-2 DP Manual page 419

Sinamics g120d cu240d-2 series; sinamics g120d cu250d-2 series
Hide thumbs Also See for SINAMICS G120D CU240D-2 DP:
Table of Contents

Advertisement

Value:
0:
1:
Dependency:
Refer to: r7760, p7761
p7763
KHP OEM exception list number of indices for p7764 / KHP OEM qty p7764
Access level: 3
Can be changed: U, T
Unit group: -
Min
1
Description:
Sets the number of parameters for the OEM exception list (p7764[0...n]).
p7764[0...n], with n = p7763 - 1
Dependency:
Refer to: p7764
Note:
KHP: Know-How Protection
Even if know-how protection is set, parameters in this list can be read and written to.
p7764[0...n]
KHP OEM exception list / KHP OEM excep list
Access level: 3
Can be changed: U, T
Unit group: -
Min
0
Description:
OEM exception list (p7764[0...n] for setting parameters that should be excluded from know-how protection.
p7764[0...n], with n = p7763 - 1
Dependency:
The number of indices depends on p7763.
Refer to: p7763
Note:
KHP: Know-How Protection
Even if know-how protection is set, parameters in this list can be read and written to.
p7765
KHP configuration / KHP config
Access level: 3
Can be changed: U, T
Unit group: -
Min
-
Description:
Configuration settings for know-how protection.
For bit 00, 01:
When KHP is activated, this means that the OEM can define whether the parameters and DCC data encrypted on the
memory card should be protected before using on other memory cards/Control Units.
For bit 02:
This means that the OEM can define whether it is possible or not to trace the drive data using the device trace
function although KHP is activated.
Bit field:
Bit
00
01
02
Dependency:
Refer to: p7766, p7767, p7768
Note:
KHP: Know-How Protection
For copy protection, the serial numbers of the memory card and/or Control Unit are checked.
The memory card copy protection and preventing data to be traced are only effective when the know-how protection
has been activated.
SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313
Write access independent of p7761
Write access dependent on p7761
Signal name
Extended copy protection - linked to the
memory card and CU
Basic copy protection - linked to the
memory card
Permit trace and measuring functions for
diagnostic purposes
Calculated: -
Scaling: -
Unit selection: -
Max
500
Calculated: -
Scaling: -
Unit selection: -
Max
65535
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Yes
Yes
Yes
2 Parameters
2.2 List of parameters
Data type: Unsigned16
Dyn. index: -
Func. diagram: -
Factory setting
1
Data type: Unsigned16
Dyn. index: p7763
Func. diagram: -
Factory setting
[0] 7766
[1...499] 0
Data type: Unsigned16
Dyn. index: -
Func. diagram: -
Factory setting
0000 bin
0 signal
No
No
No
FP
-
-
-
419

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g120d cu250d-2 pn-fSinamics g120d cu240d-2 pnSinamics g120d cu240d-2 pn-fSinamics g120d cu250d-2 dp-f

Table of Contents