2 Parameters
2.2 List of parameters
r1508
CO: Torque setpoint before supplementary torque / M_set bef. M_suppl
Access level: 2
Can be changed: -
Unit group: 7_1
Min
- [Nm]
Description:
Displays the torque setpoint before entering the supplementary torque.
For closed-loop speed control, r1508 corresponds to the speed controller output; for closed-loop torque control,
r1508 corresponds to the torque setpoint of the signal source assigned in p1503.
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
p1511[0...n]
CI: Supplementary torque 1 / M_suppl 1
Access level: 3
Can be changed: T
Unit group: -
Min
-
Description:
Sets the signal source for supplementary torque 1.
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
p1512[0...n]
CI: Supplementary torque 1 scaling / M_suppl 1 scal
Access level: 3
Can be changed: T
Unit group: -
Min
-
Description:
Sets the signal source for scaling the supplementary torque 1.
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
p1513[0...n]
CI: Supplementary torque 2 / M_suppl 2
Access level: 3
Can be changed: T
Unit group: -
Min
-
Description:
Sets the signal source for supplementary torque 2.
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
p1514[0...n]
Supplementary torque 2 scaling / M_suppl 2 scal
Access level: 3
Can be changed: U, T
Unit group: -
Min
-2000.0 [%]
Description:
Sets the scaling for supplementary torque 2.
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
220
Calculated: -
Scaling: p2003
Unit selection: p0505
Max
- [Nm]
Calculated: -
Scaling: p2003
Unit selection: -
Max
-
Calculated: -
Scaling: PERCENT
Unit selection: -
Max
-
Calculated: -
Scaling: p2003
Unit selection: -
Max
-
Calculated: -
Scaling: PERCENT
Unit selection: -
Max
2000.0 [%]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 6030, 6060, 6722
Factory setting
- [Nm]
Data type: U32 / FloatingPoint32
Dyn. index: CDS, p0170
Func. diagram: 6020, 6060
Factory setting
0
Data type: U32 / FloatingPoint32
Dyn. index: CDS, p0170
Func. diagram: 5060, 6060
Factory setting
0
Data type: U32 / FloatingPoint32
Dyn. index: CDS, p0170
Func. diagram: 6020, 6060
Factory setting
0
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 6020, 6060
Factory setting
100.0 [%]
SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313