2 Parameters
2.2 List of parameters
Value:
0:
1:
2:
Dependency:
If p0100 is changed, all of the rated motor parameters are reset. Only then are possible unit changeovers made.
The units of all motor parameters are changed that are involved in the selection of IEC or NEMA (e.g. r0206, p0307,
r0333, r0334, p0341, p0344, r1969).
Refer to: r0206, p0210, p0300, p0304, p0305, p0307, p0308, p0309, p0310, p0311, p0314, p0320, p0322, p0323,
p0335, r0337, p1800
Note:
The parameter value is not reset when the factory setting is restored (p0010 = 30, p0970).
p0124[0...n]
CU detection via LED / CU detection LED
Access level: 3
Can be changed: U, T
Unit group: -
Min
0
Description:
Identification of the Control Unit using an LED.
Note:
While p0124 = 1, the READY LED flashes green/orange or red/orange with 2 Hz at the appropriate Control Unit.
p0133[0...n]
Motor configuration / Motor config
Access level: 2
Can be changed: C(1, 3)
Unit group: -
Min
-
Description:
Configuration of the motor when commissioning the motor.
Bit field:
Bit
00
01
Dependency:
For standard induction motors (p0301 > 10000), bit 0 is automatically pre-assigned the connection type of the
selected data set.
For p0100 > 0 (60 Hz rated motor frequency), it is not possible to select bit 1.
Refer to: p0304, p0305, p1082
Note:
For bit 00:
When changing the bits, the rated motor voltage p0304 and the rated motor current p0305 are automatically
converted to the selected connection type (star/delta).
For bit 01:
87 Hz operation is only possible in the delta connection type. When selected, the maximum speed p1082 is
automatically pre-assigned for a maximum output frequency of 87 Hz.
p0170
Number of Command Data Sets (CDS) / CDS count
Access level: 2
Can be changed: C(15)
Unit group: -
Min
2
Description:
Sets the number of Command Data Sets (CDS).
Dependency:
Refer to: p0010, r3996
Notice:
When the data sets are created, short-term communication interruptions may occur.
Note:
It is possible to toggle between command parameters (BICO parameters) using this data set changeover.
48
IEC-Motor (50 Hz, SI units)
NEMA motor (60 Hz, US units)
NEMA motor (60 Hz, SI units)
Signal name
Motor connection type
Motor 87 Hz operation
Calculated: -
Scaling: -
Unit selection: -
Max
1
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Delta
Yes
Calculated: -
Scaling: -
Unit selection: -
Max
4
Data type: Unsigned8
Dyn. index: PDS
Func. diagram: -
Factory setting
0
Data type: Unsigned16
Dyn. index: MDS
Func. diagram: -
Factory setting
0000 bin
0 signal
Star
No
Data type: Unsigned8
Dyn. index: -
Func. diagram: 8560
Factory setting
2
SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313