PDE 0 RTG
5 ... 9999
p20161 (9999)
PDE 0 inp_pulse I
p20158
(0)
PDE 1 RTG
5 ... 9999
p20166 (9999)
PDE 1 inp_pulse I
p20163
(0)
1
2
Free function blocks - Time function blocks
PDE 0 ... 3
PDE (ON delay)
PDE 0
PDE 0 t_del ms
0.00 ... 5400000.00
p20159 (0.00)
T
PDE 0 output Q
T
0
I
Q
r20160
PDE 0 RunSeq
0 ... 32000
p20162 (430)
PDE 1
PDE 1 t_del ms
0.00 ... 5400000.00
p20164 (0.00)
T
PDE 1 output Q
T
0
I
Q
r20165
PDE 1 RunSeq
0 ... 32000
p20167 (440)
3
4
PDE 2
PDE 2 RTG
PDE 2 t_del ms
5 ... 9999
0.00 ... 5400000.00
p20337 (9999)
p20335 (0.00)
PDE 2 inp_pulse I
p20334
T
0
I
(0)
PDE 2 RunSeq
0 ... 32000
p20338 (890)
PDE 3
PDE 3 RTG
PDE 3 t_del ms
5 ... 9999
0.00 ... 5400000.00
p20342 (9999)
p20340 (0.00)
PDE 3 inp_pulse I
p20339
T
0
I
(0)
PDE 3 RunSeq
0 ... 32000
p20343 (900)
5
6
Function diagram
fp_7232_97_61.vsd
G120D CU240D-2
09.12.2015
V4.7.6
T
PDE 2 output Q
Q
r20336
T
PDE 3 output Q
Q
r20341
7
8
- 7232 -