Siemens SINAMICS G120D CU240D-2 DP Manual page 238

Sinamics g120d cu240d-2 series; sinamics g120d cu250d-2 series
Hide thumbs Also See for SINAMICS G120D CU240D-2 DP:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
p1731[0...n]
Isd controller combination current time component / Isd ctr I_combi T1
Access level: 4
Can be changed: U, T
Unit group: -
Min
0.00 [ms]
Description:
Sets the time constant to calculate the d current DC component difference (combination current) to add to the d
current controller actual value.
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1), "Dynamic Drive Control" (DDC, p0096
= 2)
Note:
It is not added for p1731 = 0.
r1732[0...1]
CO: Direct-axis voltage setpoint / Direct U set
Access level: 3
Can be changed: -
Unit group: 5_1
Min
- [Vrms]
Description:
Display and connector output for the direct axis voltage setpoint Ud.
Index:
[0] = Unsmoothed
[1] = Smoothed with p0045
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
r1733[0...1]
CO: Quadrature-axis voltage setpoint / Quad U set
Access level: 3
Can be changed: -
Unit group: 5_1
Min
- [Vrms]
Description:
Display and connector output for the quadrature axis voltage setpoint Uq.
Index:
[0] = Unsmoothed
[1] = Smoothed with p0045
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
p1740[0...n]
Gain resonance damping for encoderless closed-loop control / Gain res_damp
Access level: 3
Can be changed: U, T
Unit group: -
Min
0.000
Description:
Defines the gain of the controller for resonance damping for operation with sensorless vector control in the range that
current is injected.
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
p1744[0...n]
Motor model speed threshold stall detection / MotMod n_thr stall
Access level: 4
Can be changed: U, T
Unit group: 3_1
Min
0.00 [rpm]
Description:
Sets the speed threshold value to detect a stalled motor.
238
Calculated: p0340 = 1,3,4
Scaling: -
Unit selection: -
Max
10000.00 [ms]
Calculated: -
Scaling: p2001
Unit selection: p0505
Max
- [Vrms]
Calculated: -
Scaling: p2001
Unit selection: p0505
Max
- [Vrms]
Calculated: p0340 = 1,3,4
Scaling: -
Unit selection: -
Max
10.000
Calculated: p0340 = 1,3
Scaling: -
Unit selection: p0505
Max
210000.00 [rpm]
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: -
Factory setting
0.00 [ms]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 5700, 5714, 6714,
5718
Factory setting
- [Vrms]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 5700, 5714, 5718,
6714, 6719
Factory setting
- [Vrms]
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: -
Factory setting
0.025
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: -
Factory setting
100.00 [rpm]
SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g120d cu250d-2 pn-fSinamics g120d cu240d-2 pnSinamics g120d cu240d-2 pn-fSinamics g120d cu250d-2 dp-f

Table of Contents