2 Parameters
2.2 List of parameters
Note:
When the parameter is changed, all of the motor parameters (p0305 ... p0311), the technological application (p0500)
and the control mode (p1300) are pre-assigned according to the selected application. The parameter has no
influence when calculating the thermal overload.
p0205 can only be changed to the settings that are saved in the power unit EEPROM.
r0206[0...4]
Rated power unit power / PU P_rated
Access level: 2
Can be changed: -
Unit group: 14_6
Min
- [kW]
Description:
Displays the rated power unit power for various load duty cycles.
Index:
[0] = Rated value
[1] = Load duty cycle with low overload
[2] = Load duty cycle with high overload
[3] = S1 cont duty cyc
[4] = S6 load duty cycle
Dependency:
IECdrives (p0100 = 0): Units kW
NEMA drives (p0100 = 1): Units hp
Refer to: p0100, p0205
r0207[0...4]
Rated power unit current / PU PI_rated
Access level: 3
Can be changed: -
Unit group: -
Min
- [Arms]
Description:
Displays the rated power unit power for various load duty cycles.
Index:
[0] = Rated value
[1] = Load duty cycle with low overload
[2] = Load duty cycle with high overload
[3] = S1 cont duty cyc
[4] = S6 load duty cycle
Dependency:
Refer to: p0205
r0208
Rated power unit line supply voltage / PU U_rated
Access level: 2
Can be changed: -
Unit group: -
Min
- [Vrms]
Description:
Displays the rated line supply voltage of the power unit.
r0208 = 400: 380 - 480 V +/-10 %
r0208 = 500: 500 - 600 V +/-10 %
r0208 = 690: 660 - 690 V +/-10 %
r0209[0...4]
Power unit maximum current / PU I_max
Access level: 3
Can be changed: -
Unit group: -
Min
- [Arms]
Description:
Displays the maximum output current of the power unit.
52
Calculated: -
Scaling: -
Unit selection: p0100
Max
- [kW]
Calculated: -
Scaling: -
Unit selection: -
Max
- [Arms]
Calculated: -
Scaling: -
Unit selection: -
Max
- [Vrms]
Calculated: -
Scaling: -
Unit selection: -
Max
- [Arms]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: -
Factory setting
- [kW]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 8021
Factory setting
- [Arms]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: -
Factory setting
- [Vrms]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 8750, 8850, 8950
Factory setting
- [Arms]
SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313