Siemens SINAMICS G120D CU240D-2 DP Manual page 200

Sinamics g120d cu240d-2 series; sinamics g120d cu250d-2 series
Hide thumbs Also See for SINAMICS G120D CU240D-2 DP:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
p1331[0...n]
Voltage limiting / U_lim
Access level: 3
Can be changed: U, T
Unit group: 5_1
Min
50.00 [Vrms]
Description:
Limiting the voltage setpoint.
This means that the output voltage can be reduced with respect to the calculated maximum voltage r0071 and the
start of field weakening.
Dependency:
Not visible with application class: "Dynamic Drive Control" (DDC, p0096 = 2)
Note:
The output voltage is only limited if, as a result of p1331, the maximum output voltage (r0071) is fallen below.
p1333[0...n]
U/f control FCC starting frequency / U/f FCC f_start
Access level: 3
Can be changed: U, T
Unit group: -
Min
0.00 [Hz]
Description:
Sets the starting frequency at which FCC (Flux Current Control) is activated.
Dependency:
The correct operating mode must be set (p1300 = 1, 6).
Not visible with application class: "Dynamic Drive Control" (DDC, p0096 = 2)
Warning:
An excessively low value can result in instability.
Note:
For p1333 = 0 Hz, the FCC starting frequency is automatically set to 6 % of the rated motor frequency.
p1334[0...n]
U/f control slip compensation starting frequency / Slip comp start
Access level: 3
Can be changed: U, T
Unit group: -
Min
0.00 [Hz]
Description:
Sets the starting frequency of the slip compensation.
Dependency:
Not visible with application class: "Dynamic Drive Control" (DDC, p0096 = 2)
Note:
For p1334 = 0, the starting frequency of the slip compensation is automatically set to 6 % of the rated motor
frequency.
p1335[0...n]
Slip compensation scaling / Slip comp scal
Access level: 3
Can be changed: U, T
Unit group: -
Min
0.0 [%]
Description:
Sets the setpoint for slip compensation in [%] referred to r0330 (motor rated slip).
p1335 = 0.0 %: Slip compensation de-activated.
p1335 = 100.0 %: The slip is completely compensated.
Dependency:
Prerequisite for a precise slip compensation for p1335 = 100 % are the precise motor parameters (p0350 ... p0360).
If the parameters are not precisely known, a precise compensation can be achieved by varying p1335.
For U/f control types with Eco optimization (4 and 7), the slip compensation must be activated in order to guarantee
correct operation.
Not visible with application class: "Dynamic Drive Control" (DDC, p0096 = 2)
200
Calculated: -
Scaling: -
Unit selection: p0505
Max
2000.00 [Vrms]
Calculated: p0340 = 1
Scaling: -
Unit selection: -
Max
3000.00 [Hz]
Calculated: p0340 = 1
Scaling: -
Unit selection: -
Max
3000.00 [Hz]
Calculated: -
Scaling: -
Unit selection: -
Max
600.0 [%]
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 6300
Factory setting
1000.00 [Vrms]
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 6301
Factory setting
0.00 [Hz]
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 6310
Factory setting
0.00 [Hz]
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 6300, 6310
Factory setting
0.0 [%]
SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g120d cu250d-2 pn-fSinamics g120d cu240d-2 pnSinamics g120d cu240d-2 pn-fSinamics g120d cu250d-2 dp-f

Table of Contents