Record friction characteristic
Frict rec t_warm
0.000 ... 3600.000 [s]
p3847 [D] (0.000)
Frict rec act
0 ... 3
p3845 (0)
<1>
Play friction characteristic
n_act [rpm]
r0063
Sign
+ or -
n_act [rpm]
r0063
[0]
<1>
p3845
= 0: Friction characteristic record deactivated
= 1: Friction char record activated for all directions
= 2: Friction char record activated for positive direction
= 3: Friction char record activated for negative direction
1
2
Technology functions
Friction characteristic
Drive ON from the sequence control
Friction characteristic record active (p3845 > 0)
Friction M0
Friction M9
p3830 [D]
p3839 [D]
M [Nm]
n [rpm]
Friction n0
Friction n9
p3820 [D]
p3829 [D]
Friction characteristic positive direction
r3840.8
3
4
Frict rec t_RU/RD
0.000 ... 999999.000 [s]
p3846 [D] (10.000)
Start ramp-function generator
M_max lower eff [Nm]
[6640.8]
r1539
Friction characteristic OK
r3840.0
Frict act
A07960
p3842
"Friction characteristic incorrect"
1
0
0
M_max upper eff [Nm]
[6640.8]
r1538
5
fp_7010_97_53.vsd
09.12.2015
Friction ZSW
r3840
r3840
Friction characteristic record activated
r3840.1
Friction characteristic record completed
r3840.2
[3080.7]
Friction characteristic record aborted
r3840.3
A07961
"Friction characteristic record activated"
F07963
"Friction characteristic record
interrupted"
Frict outp [Nm]
[6710.1]
r3841
6
7
Function diagram
SINAMICS G120D
V4.7.6
8
- 7010 -

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g120d cu250d-2 pn-fSinamics g120d cu240d-2 pnSinamics g120d cu240d-2 pn-fSinamics g120d cu250d-2 dp-f

Table of Contents