The maximum distance differs depending on the Ethernet device to be used.
The following shows the number of the connectable nodes when a repeater hub is used.
• 10BASE-T: Max. 4 nodes for a cascade connection (500m)
• 100BASE-TX: Max. 2 nodes for a cascade connection (205m)
When switching hubs are used, the cascade connection between the switching hubs has no logical limit for the number of
cascades.
For the limit, contact the switching hub manufacturer.
*6
For the system configuration of high speed data logger module, refer to the following manual.
*7
For the system configuration of the BOX data logger, refer to the following manual.
*8
For the system configuration of the PLC CPU with the built-in Ethernet interface, refer to the following manual.
*9
Applicable only with the Display I/F connection
For the system configuration for the CNC C80 side, refer to the following manual.
*10
Applicable only with the Display I/F connection
For the system configuration for the CNC C70 side, refer to the following manual.
■3. Required hardware
A data strage is necessary in the following cases.
• Displaying or managing logging data stored in a data strage
• Reading out and displaying logging data of 4MB or more from the controller
12.2.2

GOT side settings

■1. Setting communication interface
To use the log viewer function, assign an IP address to the GOT by one of the following methods.
After completing the setting on GT Designer3 (GOT2000), write the package data to the GOT.
(1) When using the standard Ethernet interface
Set [Destination I/F] of [Ethernet Download] in the [PC (Data Transfer)] dialog.
Set an Ethernet driver in [Driver] in the [Controller Setting] dialog.
Select [Communication Setting] of [Gateway] in the [Controller Setting] dialog, and
select [Use the function of Gateway].
(2) When using the extended Ethernet interface
Set [GOT Extended IP Address] in the [GOT Standard Ethernet Setting] dialog.
For the details of the [GOT Standard Ethernet Setting] dialog, refer to the following.
(3) When using the wireless LAN extension interface
For the setting to use the wireless LAN extension interface, refer to the following.
■2. Required system application (extended function)
For the system application (extended function) required, refer to the following.
(1) System application (extended function)
Write the package data that contains the system application (extended function) for the log viewer to the GOT.
For the communication method with the GOT, refer to the following.
(2) System application (extended function) size
To install a system application (extended function) to the GOT, enough space in the user area is required.
For information on how to check the available space of the user area and each data size, refer to the following.
12 - 4
12.2 Specifications
High Speed Data Logger Module User's Manual
BOX data logger User's Manual
MELSEC iQ-R Module Configuration Manual
QnUCPU User's Manual (Communication via Built-in Ethernet Port)
MELSEC-L CPU Module User's Manual (Built-In Ethernet Function)
C80 Series Connection and Setup Manual
C70 Setup Manual
Setting method
GT Designer3 (GOT2000) Screen Design Manual
GT Designer3 (GOT2000) Screen Design Manual
1.2 System Applications (Extended Functions) Required for Each Function
GT Designer3 (GOT2000) Screen Design Manual
GT Designer3 (GOT2000) Screen Design Manual
Reference
GT Designer3 (GOT2000) Screen Design
Manual
GOT2000 Series Connection Manual
(Mitsubishi Products) For GT Works3
Version1
GT Designer3 (GOT2000) Screen Design
Manual