4.2 SERVICE CALL CONDITIONS

4.2.1 SUMMARY
There are 2 levels of service call conditions.
Level
Fusing unit SCs displayed on the
operation panel. The machine is disabled.
A
The user cannot reset the SC.
Turning the operation switch or main
power switch off then on resets the SC.
B
Displayed on the operation panel. Re-
displayed if they occurred after the main
power switch is turned on again.
All SCs are logged.
• The number of SC codes detected can be checked with SP7-902.
• Printing logging data (SP5-990-004) in SP mode can check the latest 10 SC
codes detected and total counters when the SC code is detected.
NOTE: 1) If the problem concerns electrical circuit boards, first disconnect then
reconnect the connectors before replacing the PCBs.
2) If the problem concerns a motor lock, first check the mechanical load
before replacing motors or sensors.

SC Classification

SC codes are classified by section as shown in the following table:
Class 1
1XX
Scanning
Laser exposure
2XX
Image development 1
3XX
Image development 2
4XX
Paper feed / Fusing
5XX
SM
Definition
Section
SC Code
190 -
200 -
220 -
230 -
240 -
260 -
280 -
300 -
330 -
350 -
380 -
400 -
420 -
430 -
440 -
460 -
480 -
500 -
515 -
520 -
4-7
SERVICE CALL CONDITIONS
Reset Procedure
Turn the main switch off then on
before entering SP mode. Reset
the SC (set SP5-810 to 1), then
turn the main switch off then on
again.
Turn the operation switch or
main power switch off and on.
Detailed section
Unique for a specific model
Polygon motor
Synchronization control
FGATE signal related
LD control
Magnification
Unique for a specific model
Charge
Drum potential
Development
Unique for a specific model
Image transfer
Paper separation
Cleaning
Around drum
Unit
Others
Paper feed
Duplex
Paper transport
G060