Request Virtual-Chassis Vc-Port - Juniper JUNOS OS 10.4 - FOR EX REV 1 Manual

For ex series ethernet switches
Table of Contents

Advertisement

request virtual-chassis vc-port

Syntax
Release Information
Description
Options
Required Privilege
Level
Related
Documentation
List of Sample Output
request virtual-chassis
request virtual-chassis
vc-port set pic-slot 1
vc-port set pic-slot 1
port 0
port 0
request virtual-chassis
vc-port set pic-slot 1
port 1 member 3
request virtual-chassis
vc-port delete pic-slot
1 port 1 member 3
Copyright © 2010, Juniper Networks, Inc.
request virtual-chassis vc-port set | delete pic-slot pic-slot port port-number
<member member-id>
Command introduced in Junos OS Release 9.0 for EX Series switches.
Enable or disable an uplink module port (on an SFP, SFP+, or XFP uplink module) or an
SFP network port as a Virtual Chassis port (VCP).
If you omit
member member-id
VCP or SFP network port configured as a VCP on the switch where the command is
issued.
pic-slot pic-slot
—Number of the PIC slot for the uplink module port or SFP network port
on the switch.
—Number of the uplink module port or SFP network port that is to be
port port-number
enabled or disabled as a VCP.
member member-id
—(Optional) Enable or disable the specified VCP on the specified
member of the Virtual Chassis configuration.
system-control
request virtual-chassis vc-port on page 1046 (dedicated port)
show virtual-chassis vc-port on page 1058
show virtual-chassis vc-port statistics on page 1062
clear virtual-chassis vc-port statistics on page 1040
Virtual Chassis Port (VCP) Interface Names in an EX8200 Virtual Chassis on page 1083
Understanding EX4200 Virtual Chassis Components on page 893
request virtual-chassis vc-port set pic-slot 1 port 0 on page 1127
request virtual-chassis vc-port set pic-slot 1 port 1 member 3 on page 1127
request virtual-chassis vc-port delete pic-slot 1 port 1 member 3 on page 1127
user@host>request virtual-chassis vc-port set pic-slot 1 port 0
To check the results of this command, use the show virtual-chassis vc-port command.
user@host>request virtual-chassis vc-port set pic-slot 1 port 1 member 3
To check the results of this command, use the show virtual-chassis vc-port command.
user@host>request virtual-chassis vc-port delete pic-slot 1 port 1 member 3
To check the results of this command, use the show virtual-chassis vc-port command.
Chapter 49: Operational Commands for EX8200 Virtual Chassis
, this command defaults to enabling or disabling the uplink
1127

Advertisement

Table of Contents
loading

This manual is also suitable for:

Junos os 10.4

Table of Contents