Verification
Purpose
Action
Meaning
Related
Documentation
Copyright © 2010, Juniper Networks, Inc.
[edit virtual-chassis]
user@switch# show
auto-sw-update {
package-name /var/tmp/jinstall-ex-4200-10.0R1.1-domestic-signed.tgz;
}
To verify that the software version on the new switch has been updated and that the
switch has joined the Virtual Chassis configuration, perform this task:
Verifying That the Software Version Is Updated on page 979
Verifying That the Software Version Is Updated
Verify that the new switch has joined the Virtual Chassis configuration.
NOTE: If the software version on the new switch had not been updated
successfully, the master would not allow the switch to join the Virtual Chassis
configuration.
Issue the
1.
show virtual-chassis status
Check to see that the new member switch has been added.
2.
user@switch> show virtual-chassis status
Virtual Chassis ID: 0019.e250.47a0
Member ID
Status
Serial No
0 (FPC 0)
Prsnt
AK0207360276 ex4200-24t
1 (FPC 1)
Prsnt
AK0207360281 ex4200-24t
2 (FPC 2)
Prsnt
AJ0207391130 ex4200-48p
Because in the initial two-member Virtual Chassis configuration member 0 was the
master and member 1 was the backup, the output shows that the new switch has been
assigned member ID
and has been given the
2
member 2 is
, which means that it is in the active state.
Prsnt
Configuring Automatic Software Update on EX4200 Virtual Chassis Member Switches
(CLI Procedure) on page 1004
Adding a New Switch to an Existing EX4200 Virtual Chassis (CLI Procedure) on page 986
Chapter 38: EX4200 Virtual Chassis—Configuration Examples
command.
Mastership
Model
priority
Role
255
Master*
255
Backup
128
Linecard
role. The
Linecard
Neighbor List
ID
Interface
1
vcp-1
2
vcp-0
2
vcp-1
0
vcp-0
0
vcp-1
1
vcp-0
field shows that
Status