OS for EX Series Ethernet Switches, Release 10.4
Ensured that the new member switch has the factory-default configuration. If the new
member switch has been previously configured, revert its configuration to the factory
defaults. See "Reverting to the Default Factory Configuration for the EX Series Switch"
on page 415.
Made a note of the serial number (on the back of the switch). You will need to edit the
Virtual Chassis configuration to include the serial number of the new member switch.
Edited the existing Virtual Chassis preprovisioned configuration to include the serial
number of the new member switch. You can specify the role of the new member switch
when you add its serial number to the Virtual Chassis configuration file. The parameters
specified in the master Virtual Chassis configuration file are applied to the new member
switch after it has been interconnected through its uplink VCP to an existing member
switch.
Prepared an existing member switch to interconnect with the new switch through an
uplink module port by configuring an uplink module port as a VCP on the existing
member switch.
Ensured that the operational modes of the uplink modules on the existing member
switch and the new member switch match.
Confirmed that the new member switch is powered off.
Interconnected the existing switch with the new switch using the appropriate cable.
If these conditions are not met, autoprovisioning will not work and you will need to
manually configure uplink module ports on the switch to be added to the configuration
to be VCPs. For more information, see "Setting an EX4200 Switch Uplink Module Port
as a Virtual Chassis Port (CLI Procedure)" on page 994.
To add a switch to an existing preprovisioned EX4200 Virtual Chassis configuration using
the autoprovisioning feature:
Power on the new member switch.
1.
Confirm that the new member switch is now included in the Virtual Chassis
2.
configuration by checking the front-panel LCD for the member ID. It should display a
member ID in the range from 0 through 9. The member ID is automatically assigned
to the new member switch's serial number in the configuration file.
Example: Expanding an EX4200 Virtual Chassis in a Single Wiring Closet on page 922
Example: Setting Up a Multimember EX4200 Virtual Chassis Access Switch with a
Default Configuration on page 927
Example: Configuring an EX4200 Virtual Chassis Interconnected Across Multiple Wiring
Closets on page 932
Example: Configuring an EX4200 Virtual Chassis Using a Preprovisioned Configuration
File on page 952
Example: Configuring Automatic Software Update on EX4200 Virtual Chassis Member
Switches on page 977
Monitoring EX4200 Virtual Chassis Status and Statistics on page 1013
Copyright © 2010, Juniper Networks, Inc.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Junos os 10.4

Table of Contents