between the switch's serial number and a member ID, using a preprovisioned configuration.
Or you can let the member ID be assigned by the master, based on the sequence in which
the member switch is powered on and on which member IDs are currently available.
The role and member ID of the member switch are displayed on the front-panel LCD.
Each member switch can be cabled to one or two other member switches, using either
the dedicated Virtual Chassis ports (VCPs) on the rear panel, an uplink module port that
has been configured as a VCP, or an SFP network port on an EX4200-24F switch that
has been configured as a VCP. The members that are cabled together are considered
neighbor members.
To display the role and member ID assignments using the CLI, use the
status
command:
user@switch> show virtual-chassis status
Virtual Chassis ID: 0000.e255.00e0
Member ID
Status
Serial No
0 (FPC 0)
Prsnt
abc123
1 (FPC 1)
Prsnt
def456
2 (FPC 2)
Prsnt
abd231
This output verifies that three EX4200 switches have been interconnected as a Virtual
Chassis configuration through their dedicated VCPs . The display shows which of the
VCPs is connected to which neighbor. The first port (
to member
1
and the second port of member
FPC slots for the switches are the same as the member IDs.
The
values indicate that the master and backup members have been
Mastership Priority
explicitly configured, because they are not using the default value (
Configuring Mastership of the EX4200 Virtual Chassis (CLI Procedure) on page 992
Configuring an EX4200 Virtual Chassis (CLI Procedure) on page 981
Configuring an EX4200 Virtual Chassis (J-Web Procedure) on page 985
Example: Expanding an EX4200 Virtual Chassis in a Single Wiring Closet on page 922
Example: Setting Up a Multimember EX4200 Virtual Chassis Access Switch with a
Default Configuration on page 927
Monitoring EX4200 Virtual Chassis Status and Statistics on page 1013
Chapter 40: Verifying EX4200 Virtual Chassis Configuration
Mastership
Model
Priority
Role
ex4200-48p
255
Master*
ex4200-24t
255
Backup
ex4200-24p
128
Linecard
) of member
vcp-0
0
(
vcp-1
) is connected to member
show virtual-chassis
Neighbor List
ID, Interface
1 vcp-0
2 vcp-1
2 vcp-0
0 vcp-1
0 vcp-0
1 vcp-1
is connected
0
2
. The
128
).
1011