Juniper JUNOS OS 10.4 - FOR EX REV 1 Manual page 1122

For ex series ethernet switches
Table of Contents

Advertisement

Complete Software Guide for Junos
Member ID Persists When a Member Switch Is Disconnected From an EX4200 Virtual Chassis
Problem
Solution
Related
Documentation
1018
®
OS for EX Series Ethernet Switches, Release 10.4
Gigabit Ethernet interfaces retain their previous slot numbers when a member switch is
disconnected from the EX4200 Virtual Chassis.
If a switch had been previously connected as a member of a Virtual Chassis configuration,
it retains the member ID that it was assigned as a member of that configuration even
after it is disconnected and operating as a standalone switch. The interfaces that were
configured while the switch was a member of the Virtual Chassis configuration retain
the old member ID as the first digit of the interface name.
For example, if the switch was previously member
and so on.
To change the switch's member ID, so that its member ID is
interfaces accordingly:
To change the member ID to 0:
1.
user@switch> request virtual-chassis renumber member-id 1 new-member-id 0
To rename the interfaces to match the new member ID:
2.
[edit virtual-chassis]
user@switch# replace pattern ge-1/ with ge-0/
Monitoring EX4200 Virtual Chassis Status and Statistics on page 1013
Configuring an EX4200 Virtual Chassis (CLI Procedure) on page 981
Configuring an EX4200 Virtual Chassis (J-Web Procedure) on page 985
For more information about the
http://www.juniper.net/techpubs/software/junos/index.html
, its interfaces are named
1
0
, and to rename the switch's
command, see Junos OS CLI User Guide at
replace