Troubleshooting
Problem
Solution
Related
Documentation
Copyright © 2010, Juniper Networks, Inc.
Destination: 10.10.10/24, Local: 10.10.10.1, Broadcast: 10.10.10.255
The output here shows that the link is down and that no PDUs are being exchanged.
To troubleshoot a nonworking LACP link, perform these tasks:
Troubleshooting a Nonworking LACP Link
The LACP link is not working.
Check the following:
Remove the LACP configuration and verify whether the static LAG is up.
Verify that LACP is configured at both ends.
Verify that LACP is not passive at both ends.
Verify whether LACP protocol data units (PDUs) are being exchanged by running the
monitor traffic-interface lag-member detail
Example: Connecting an Access Switch to a Distribution Switch on page 1540
Virtual Chassis Cabling Configuration Examples for EX4200 Switches
Installing an Uplink Module in an EX4200 Switch
Chapter 38: EX4200 Virtual Chassis—Configuration Examples
command.