Member - Juniper JUNOS OS 10.4 - FOR EX REV 1 Manual

For ex series ethernet switches
Table of Contents

Advertisement

Copyright © 2010, Juniper Networks, Inc.
NOTE: The settings of the uplink VCPs remain intact when SWA-2
reboots and joins the Virtual Chassis configuration as member 2.
user@SWA-2> request virtual-chassis vc-port set pic-slot 1 port 0
user@SWA-2> request virtual-chassis vc-port set pic-slot 1 port 1
Power down SWA-2.
8.
Physically interconnect SWA-0 and SWA-2 across wiring closets using two of the
9.
uplink VCPs on each switch.
Power on SWA-2. SWA-2 joins the Virtual Chassis configuration and a LAG is
10.
automatically formed between SWA-0 and SWA-2. In addition, although SWA-0
and SWA-2 have the same mastership priority value (255), SWA-0 was powered
on first and thus has longer uptime. This results in SWA-0 retaining mastership
while SWA-2 reboots and joins the now expanded Virtual Chassis configuration as
the backup, with member ID
Power on SWA-3.
11.
If SWA-3 was previously configured, revert to the factory default configuration.
12.
Specify both XFP uplink module interfaces in SWA-3 as uplink VCPs:
13.
user@SWA-3> request virtual-chassis vc-port set pic-slot 1 port 0
user@SWA-3> request virtual-chassis vc-port set pic-slot 1 port 1
Power down SWA-3.
14.
Physically interconnect SWA-3 with SWA-2 using their dedicated VCPs.
15.
Physically interconnect SWA-1 and SWA-3 across wiring closets using their uplink
16.
VCPs.
Power on SWA-3. It joins the Virtual Chassis configuration as member
17.
NOTE: Member ID
on after members 0, 1, and 2.
A LAG is automatically formed between SWA-1 and SWA-3. In addition, both SWA-1
and SWA-3 have the default mastership priority value (128) and function in a linecard
role.
Power on SWA-4.
18.
If SWA-4 was previously configured, revert to the factory default configuration.
19.
Configure two of the network interfaces on SWA-4 as uplink VCPs:
20.
user@SWA-4> request virtual-chassis vc-port set pic-slot 0 port 20
user@SWA-4> request virtual-chassis vc-port set pic-slot 0 port 21
Power down SWA-4.
21.
Chapter 38: EX4200 Virtual Chassis—Configuration Examples
2
.
3
is assigned to SWA-3 because SWA-3 was powered
3
.
973

Advertisement

Table of Contents
loading

This manual is also suitable for:

Junos os 10.4

Table of Contents