Juniper JUNOS OS 10.4 - FOR EX REV 1 Manual page 1062

For ex series ethernet switches
Table of Contents

Advertisement

Complete Software Guide for Junos
Step-by-Step
Procedure
958
®
OS for EX Series Ethernet Switches, Release 10.4
To create a preprovisioned configuration for the Virtual Chassis:
Specify the preprovisioned configuration mode:
1.
[edit virtual-chassis]
user@SWA–0# set preprovisioned
Specify all the members that will be included in the Virtual Chassis configuration,
2.
listing each switch's serial number with the desired member ID and the desired role:
[edit virtual-chassis]
user@SWA–0# set member 0 serial-number abc123 role routing-engine
user@SWA–0# set member 1 serial-number def456 role linecard
user@SWA–0# set member 2 serial-number ghi789 role linecard
user@SWA–0# set member 3 serial-number jkl012 role linecard
user@SWA–0# set member 4 serial-number mno345 role linecard
user@SWA–0# set member 5 serial-number pqr678 role routing-engine
user@SWA–0# set member 6 serial-number stu901 role linecard
user@SWA–0# set member 7 serial-number vwx234 role linecard
user@SWA-0# set member 8 serial-number yza567 role linecard
user@SWA–0# set member 9 serial-number bcd890 role linecard
Power on the member switches in wiring closet A.
3.
Prepare the members in wiring closet A for interconnecting with the member
4.
switches in wiring closet B by setting uplink VCPs for member 0 and member 2:
user@SWA-0> request virtual-chassis vc-port set pic-slot 1 port 0
user@SWA-2> request virtual-chassis vc-port set pic-slot 1 port 0 member 2
NOTE:
For redundancy, this example sets an uplink VCP in both SWA-0 and
SWA-2.
This example omits the specification of the member
uplink for SWA-0. The command applies by default to the switch
where it is executed.
Power on SWA-5 and connect to it. This switch comes up as member ID
5.
functions as master of itself. Although SWA-5 is listed in the preprovisioned
configuration file, it is not a present member of the Virtual Chassis configuration
that has been powered on thus far. In order for the master to detect SWA-5 as a
connected member, you must first set an uplink VCP on SWA-5 and interconnect
that VCP with the uplink VCP of SWA-0.
Set the first uplink of SWA-5 to function as a VCP. Because SWA-5 has been
6.
powered on as a separate switch and is still operating independently at this point,
its member ID is
.
0
user@SWA-5> request virtual-chassis vc-port set pic-slot 1 port 0
in setting the
0
and
0
Copyright © 2010, Juniper Networks, Inc.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Junos os 10.4

Table of Contents