ABB CRB 1100 Product Manual page 59

Table of Contents

Advertisement

3
Supplying power to connector R1.MP
If the robot is not connected to the controller, power must be supplied to connector
R1.MP on the robot, in order to enable the brake release buttons.
1
2
3
Product manual - CRB 1100
3HAC078007-001 Revision: J
Action
Release the holding brake of all axes by pressing
the brake release button.
The brake will be enable as soon as the button is
released.
WARNING
Pressing the brake release button will release the
holding brakes on all axes simultaneously.
Action
DANGER
Incorrect connections, such as supplying power
to the wrong pin, may cause all brakes to be
released simultaneously and instantly!
Supply
0V on pin 12.
24V on pin 11.
Note
Do not interchange the 24V and 0V pins.
If they are mixed up, damage can be caused to
internal electrical components.
Use the brake releasing button as described in
Releasing the brakes on page
© Copyright 2021-2023 ABB. All rights reserved.
3 Installation and commissioning
3.3.3 Manually releasing the brakes
Note
xx2100000158
Note
xx1800002443
58.
Continued
59

Advertisement

Table of Contents
loading

Table of Contents