ABB CRB 1100 Product Manual page 309

Table of Contents

Advertisement

4
5
Refitting the connector interface plate
1
Product manual - CRB 1100
3HAC078007-001 Revision: J
Action
Valid for cabling with rear interface
Refit the bottom cover.
Valid for cabling with bottom interface (option
3309-1)
Refit the rear cover.
Action
Route and secure the cabling with cable straps.
CAUTION
Correct cable routing is highly important.
If the cables are routed and secured incorrectly
the cables can be damaged.
© Copyright 2021-2023 ABB. All rights reserved.
5 Repair
5.4.1 Replacing the base
Continued
Note
Screw: M3x8 Steel 8.8-A2F (7 pcs)
Tightening torque: 1.2 Nm
xx1800003035
Screw: M3x8 12.9 Lafre
2C2B/FC6.9 (6 pcs)
Tightening torque: 1.2 Nm
xx1800003057
Note
Continues on next page
309