5 Repair
5.3.2 Replacing the lower cable package
Continued
5
6
7
Continues on next page
248
Action
Remove the connector plate.
Disconnect the connector.
J1M.BR
Tip
Take photos of the connector and cable position
before disconnecting them, to have as a reference
when reconnecting.
Remove the female header of the J1M.BR connect-
or from the connector plate.