5 Repair
5.3.3 Replacing the SMB unit
Continued
Required tools and equipment
Equipment
Standard toolkit
Calibration tool box, Axis Calibra-
tion
24 VDC power supply
Required consumables and wear parts
Consumable
Cable straps
Grease
Locking liquid
Deciding calibration routine
Decide which calibration routine to be used, based on the information in the table.
Depending on which routine is chosen, action might be required prior to beginning
the repair work of the robot, see the table.
1
Continues on next page
270
Action
Decide which calibration routine to use for
calibrating the robot.
Reference calibration. External cable
packages (DressPack) and tools can
stay fitted on the robot.
Fine calibration. All external cable
packages (DressPack) and tools
must be removed from the robot.
If the robot is to be calibrated with refer-
ence calibration:
Find previous reference values for the axis
or create new reference values. These val-
ues are to be used after the repair proced-
ure is completed, for calibration of the ro-
bot.
If no previous reference values exist, and
no new reference values can be created,
then reference calibration is not possible.
If the robot is to be calibrated with fine
calibration:
Remove all external cable packages
(DressPack) and tools from the robot.
© Copyright 2021-2023 ABB. All rights reserved.
Article number
Note
-
Content is defined in section
Standard toolkit on page
3HAC074119-001
Delivered as a set of calibration
tools.
Required if Axis Calibration is the
valid calibration method for the
robot.
The tool box also includes a
unique calibration pin for CRB
1100 to be fitted to the tool flange
during calibration of axis 6.
-
Used to release the motor brakes.
Article number
Note
-
3HAC029132-001
FM 222
-
Loctite 2400 (or equivalent Loctite
243)
Note
Note
Calibrating axis 6 always requires tools to
be removed from the mounting flange (also
for reference calibration) since the mount-
ing flange is used for installation of the
calibration tool.
Follow the instructions given in the refer-
ence calibration routine on the FlexPendant
to create reference values.
Creating new values requires possibility to
move the robot.
Read more about reference calibration for
Axis Calibration in
routine on page
710.
Reference calibration
664.
Product manual - CRB 1100
3HAC078007-001 Revision: J