ABB CRB 1100 Product Manual page 282

Table of Contents

Advertisement

5 Repair
5.4.1 Replacing the base
Continued
9
10
11
12
Continues on next page
282
Action
Loosen the screws and move the motor slightly
to slacken the timing belt.
Remove the screws and washers.
Carefully lift out the motor.
CAUTION
A cooling pad is attached to the motor, which may
stick to the casting. Always use a plastic sheet
with caution to remove the pad from the casting.
Pay attention not to scratch the casting or damage
the pad.
CAUTION
Be aware of the motor cabling. The motor cannot
be removed completely until the connector is
disconnected, as shown in following step.
Remove the timing belt from its groove on the
motor.
© Copyright 2021-2023 ABB. All rights reserved.
Note
xx1800002493
xx1800002494
Cooling pad location
xx1800003603
xx1800002496
Product manual - CRB 1100
3HAC078007-001 Revision: J

Advertisement

Table of Contents
loading

Table of Contents