6
Reconnecting the air hoses, CP/CS cabling and Ethernet cabling (if equipped)
1
Product manual - CRB 1100
3HAC078007-001 Revision: J
Action
For robots with Ethernet cabling
Reconnect the connector J5.C2 using the tool.
Route and secure the cabling with cable straps.
CAUTION
Correct cable routing is highly important.
If the cables are routed and secured incorrectly
the cables can be damaged.
Refit the cover.
Action
Reconnect the air hoses in a cross pattern to the
Y-shaped connectors.
Tip
See the number markings on the air hoses for
help to find the corresponding air hoses.
The air hoses with the same number connect to
the same Y-shaped connector.
© Copyright 2021-2023 ABB. All rights reserved.
5.3.1 Replacing the upper cable package
Note
J5.C2 connector assembly tool, in-
cluded in the special toolkit
3HAC071022-001
xx1800002948
Screw: M3x8 12.9 Lafre
2C2B/FC6.9 (4 pcs)
Tightening torque: 1.2 Nm
xx2000002219
Note
xx1800002500
Continues on next page
5 Repair
Continued
227