Refitting the base cover
Notice that the procedure differs depending on if the connector interface is located
either at the rear or at the bottom of the base.
1
2
3
4
5
Product manual - CRB 1100
3HAC078007-001 Revision: J
Action
Apply grease to the cable package, cover all
moving area of the package.
Apply grease to the covers that have contacting
area with the cable package.
Route and secure the cabling with cable straps.
CAUTION
Correct cable routing is highly important.
If the cables are routed and secured incorrectly
the cables can be damaged.
Valid for cabling with rear interface
Refit the bottom cover.
Valid for cabling with bottom interface (option
3309-1)
Refit the rear cover.
© Copyright 2021-2023 ABB. All rights reserved.
5.3.2 Replacing the lower cable package
Note
Screw: M3x8 Steel 8.8-A2F (7 pcs)
Tightening torque: 1.2 Nm
xx1800003035
Screw: M3x8 12.9 Lafre
2C2B/FC6.9 (6 pcs)
Tightening torque: 1.2 Nm
xx1800003057
Continues on next page