5 Repair
5.7.4 Replacing the axis-4 motor
Continued
6
Refitting the motor
Use these procedures to refit the axis-4 motor.
Refitting the axis-4 motor
1
2
Continues on next page
518
Action
Remove the timing belt from its groove on the
motor.
Action
Check that:
all assembly surfaces are clean and without
damages
the motor is clean and undamaged.
Check the cooling pad.
Replace if damaged.
© Copyright 2021-2023 ABB. All rights reserved.
Note
xx1800003096
Note
Cooling pad for axis-3 and -4 mo-
tors: 3HAC071021-001